Users Manual Part 1

In-
dex
Cable
Part
Number
From Unit To Unit Notes
bers on
page 204.
18 3066543B
16
ATCC (3, 4) Duplexer 2 /
TX in Prime
Cabinet
TX path, Duplexer TX cable rout-
ed through conjunction hole at
side of the cabinet
19 3066543B
11
RX Splitter 1 /
Prime Cab
Duplexer 1/
Exp Cab (in
MTS 4 Prime
Cabinet)
RX path/ RX on 1 or 2 ant.
20 3066543B
11
RX Splitter 2 /
Prime Cab
Duplexer 2 /
Exp Cab (in
MTS 4 Prime
Cabinet)
RX path/ RX on 1 or 2 ant.
21 3066543B
11
RX Splitter 3 /
Prime Cab
Preselector /
Exp Cab (in
MTS 4 Prime
Cabinet)
RX path/ RX on 2 ant.
NOTICE:
In the Prime Cabinet, the cables from ATCC 1/TX OUT to Duplexer 1/TX and from ATCC 2/TX
to Duplexer 2/TX needs to be combined with a T Cable and connected to Duplexer 1/TX,
allowing Expansion Cabinet channels to be connected to Duplexer 2/TX.
When MTCC is used instead of ATCC, connect the cables to corresponding inputs and outputs.
RX cables from Filters in Prime Cabinet to RX Splitters in the Expansion Cabinet are routed
through holes on the back side of the top-lid.
6802800U74-AP
Chapter 5: Interconnection and Internal Cabling