Users Manual Part 1
In-
dex
Cable
Part Num-
ber
From Unit/ Con-
nection Name
To Unit/ Connec-
tion Name
Notes
5 3066544B
15
Base Radio 1 /
SC2
Site Controller2/
BR1
Ethernet link/ Grey cable
6 3066544B
16
Base Radio 2/
SC2
Site Controller2/
BR2
Ethernet link/ Grey cable
7 3066544B
01
Base Radio 3/
SC2
Site Controller2/
BR3
Ethernet link/ Grey cable
8 3066544B
02
Base Radio 4/
SC2
Site Controller2/
BR4
Ethernet link/ Grey cable
9 3066544B
01
Base Radio 5/
SC1
XHUB1/ BR5 Ethernet link/ Grey cable
10 3066544B
02
Base Radio 6/
SC1
XHUB1/ BR6 Ethernet link/ Grey cable
11 3066544B
04
Base Radio 7/
SC1
XHUB1/ BR7 Ethernet link/ Grey cable
12 3066544B
05
Base Radio 8/
SC1
XHUB1/ BR8 Ethernet link/ Grey cable
13 3066544B
15
Base Radio 5/
SC2
XHUB2/ BR5 Ethernet link/ Grey cable
14 3066544B
16
Base Radio 6/
SC2
XHUB2/ BR6 Ethernet link/ Grey cable
15 3066544B
01
Base Radio 7/
SC2
XHUB2/ BR7 Ethernet link/ Grey cable
16 3066544B
02
Base Radio 8/
SC2
XHUB2/ BR8 Ethernet link/ Grey cable
17 3066544B
12
Site Controller 1 /
Exp Cab port on
Site Controller 1
XHUB 1 / Prime Cab
port on XHUB 1
Routed through conjunc-
tion hole at the side of the
cabinet
18 3066544B
12
Site Controller 2 /
Exp Cab port on
Site Controller 2
XHUB 2 / Prime Cab
port on XHUB 2
Routed through conjunc-
tion hole at the side of the
cabinet
19
3066562B
01
Junction Panel/
Link1
RJ45 coupler Bend Link breakout and in-
sert RJ45 coupler.
30015009
004
RJ45 coupler XHUB Controller 1/
AUX1
Ethernet link/ Beige cable
20
3066562B
01
Junction Panel/
Link2
RJ45 coupler Bend Link breakout and in-
sert RJ45 coupler.
30015009
004
RJ45 coupler XHUB Controller 2/
AUX1
Ethernet link/ Beige cable
21
3066544B
17
Site Controller2/
Red. Out
Site Controller1/
Red. In
Ethernet link/ Blue cable,
only for configuration with
redundant Site Controller
6802800U74-AP
Chapter 5: Interconnection and Internal Cabling
192