Users Manual Part 1
5.3.3
E1 and Ethernet Cabling – MTS 4
Table 41: E1 and Ethernet Cabling for MTS 4
In-
dex
Cable
Part Num-
ber
From Unit/ Con-
nection Name
To Unit/ Connec-
tion Name
Notes
1 3066544B
01
Base Radio 1 /
SC1
Site Controller1/
BR1
Ethernet link/ Grey cable
2 3066544B
02
Base Radio 2/
SC1
Site Controller1/
BR2
Ethernet link/ Black cable
3 3066544B
04
Base Radio 3/
SC1
Site Controller1/
BR3
Ethernet link/ Grey cable
4 3066544B
05
Base Radio 4/
SC1
Site Controller1/
BR4
Ethernet link/ Black cable
5 3066544B
15
Base Radio 1 /
SC2
Site Controller2/
BR1
Ethernet link/ Grey cable,
only for configuration with
redundant Site Controller
6 3066544B
16
Base Radio 2/
SC2
Site Controller2/
BR2
Ethernet link/ Black cable,
only for configuration with
redundant Site Controller
7 3066544B
01
Base Radio 3/
SC2
Site Controller2/
BR3
Ethernet link/ Grey cable,
only for configuration with
redundant Site Controller
8 3066544B
02
Base Radio 4/
SC2
Site Controller2/
BR4
Ethernet link/ Black cable,
only for configuration with
redundant Site Controller
9 3066567B
02
Junction Panel/
E1
Y-splitter E1 link/ Green cable
3066560B
01
Y-splitter Site Controller1 Y-splitter, 8-pin, 2-jack to
1- plug
9b 3066567B
02
Y-splitter Site Controller2 E1 link/ Green cable, only
for configuration with re-
dundant Site Controller
10 3066544B
17
Site Controller2/
Red. Out
Site Controller1/
Red. In
Ethernet link/ Blue cable,
only for configuration with
redundant Site Controller
11 3066544B
17
Site Controller1/
Red. Out
Site Controller2/
Red. In
Ethernet link/ Blue cable,
only for configuration with
redundant Site Controller
6802800U74-AP
Chapter 5: Interconnection and Internal Cabling
179