5.3
E1 and Ethernet Cabling
E1 cabling refers to the cabling between Site Controller and the E1 connector on the Junction Panel.
Ethernet cabling refers to the cabling between Site Controller and Base Radios.
NOTICE: Either E1 or X.21 cabling is used, depending on which option is ordered.
5.3.1
E1 and Ethernet Cabling – MTS LiTE
Table 39: E1 and Ethernet Cabling for MTS LiTE
In-
dex
Cable
Part
Number
From Unit/ Con-
nection Name
To Unit/ Connec-
tion Name
Notes
1 3066544B
24
Base Radio 1 /
SC1
Site Controller/
BR1
Ethernet link/ Grey cable
2 3066567B
03
Site Controller/
E1
Junction Panel/ E1 E1 link/ Green cable
Figure 97: E1 and Ethernet Cabling Diagram for MTS LiTE
SITE CONTROLLER
POWER SUPPLY UNIT
FRONT VIEW
BASE RADIO
FRONT VIEW
SITE CONTROLLER
REAR VIEW
DUPLEXER
TOP VIEW
PRESELECTOR
TOP VIEW
FRONT VIEW
FRONT VIEW
FRONT VIEW
JUNCTION PANEL TOP VIEW
BASE RADIO
POWER SUPPLY
BR1
BR2
BR2
BR1
BR1
BR2
CAN
Service
Service
Red
In
BR3
Power 2
Power
Rx 1
RX
AC In
AC In Status
DC Out / Temp
Fan 1
Status
Fan 2
Status
Fan 3
Status
Battery Temp.
Sens.
DC Out.
ATTC
DC Out
DC in
Battery
CAN 1
CAN 1
CAN 2
CAN 2
DC In Status
DC in
GND
DC
Ant. 1
GPS
LINK 1 LINK 2
E1
Bat. Temp
Ant. 2
RGPS
X.21
User Alarms/Controls
AC in
Tx
TX/RX
Tx
AUX
Status
BR
Alarm
SC2
SC1
Rx 2
Rx 3
Power 1
BR4
E1
Exp. Cab
Red.
Out
Active
Mode
GPS
BTS Alarm
Reset
Reset
TX
Alarms/Control X.21/Remote GPS
GPS
5.3.2
E1 and Ethernet Cabling – MTS 2
Table 40: E1 and Ethernet Cabling for MTS 2
In-
dex
Cable
Part
Number
From Unit/ Con-
nection Name
To Unit/ Connec-
tion Name
Notes
1 3066544B
01
Base Radio 1 /
SC1
Site Controller/
BR1
Ethernet link/ Grey cable
6802800U74-AP
Chapter 5: Interconnection and Internal Cabling
176