Users Manual Part 1
In-
dex
Cable Part
Number
From Unit/ Con-
nection Name
To Unit/ Con-
nection Name
Notes
3b Door Alarm Molex connector type
Figure 94: User Alarms/Controls, X.21, RGPS, and GPS Cabling Diagram for MTS LiTE
SITE CONTROLLER
POWER SUPPLY UNIT
FRONT VIEW
BASE RADIO
FRONT VIEW
SITE CONTROLLER
REAR VIEW
DUPLEXER
TOP VIEW
PRESELECTOR
TOP VIEW
FRONT VIEW
FRONT VIEW
FRONT VIEW
JUNCTION PANEL TOP VIEW
BASE RADIO
POWER SUPPLY
BR1
BR2
BR2
BR1
BR1
BR2
CAN
Service
Service
Red
In
BR3
Power 2
Power
Rx 1
RX
AC In
AC In Status
DC Out / Temp
Fan 1
Status
Fan 2
Status
Fan 3
Status
Battery Temp.
Sens.
DC Out
ATCC
DC Out
DC in
Battery
CAN 1
CAN 1
CAN 2
CAN 2
DC In Status
DC in
GND
DC
Ant. 1
GPS
LINK 1 LINK 2
E1
Bat. Temp
Ant. 2
RGPS
X.21
User Alarms/Controls
AC in
Tx
TX/RX
Tx
AUX
Status
BR
Alarm
SC2
SC1
Rx 2
Rx 3
Power 1
BR4
E1
Exp. Cab
Red.
Out
Active
Mode
GPS
BTS Alarm
Reset
Reset
TX
Alarms/Control Alarms/Control
GPS
5.2.2
User Alarms/Controls, X.21, RGPS, and GPS Cabling – MTS 2
Table 37: User Alarms/Controls, X.21, RGPS, and GPS Cabling for MTS 2
In-
dex
Cable Part
Number
From Unit/ Con-
nection Name
To Unit/ Con-
nection Name
Notes
MTS 2 with RGPS and E1 or RGPS and X.21
2a
3066546B
01
Junction Panel/
X.21
Site Controller/
X.21/Remote
GPS
15 pin D male connector
type
2b Junction Panel/
RGPS
15 pin D female connector
type
3a
3066549B
01
Junction Panel/
User Alarms/
Controls
Site Controller/
Alarm/Controls
25 pin D female connector
type
3b Door Alarm Molex connector type
MTS 2 with Internal GPS and X.21
1 3066543B
07
Junction Panel/
GPS
Site Controller/
GPS
Coax cable
2a 3066546B
02
Junction Panel/
X.21
Site Controller/
X.21/Remote
GPS
N/A
3a
3066549B
01
Junction Panel/
User Alarms/
Controls
Site Controller/
Alarm/Controls
25 pin D female connector
type
3b Door Alarm Molex connector type
6802800U74-AP
Chapter 5: Interconnection and Internal Cabling
171