Users Manual Part 1
5.2
User Alarms/Controls, X.21, RGPS, and GPS Cabling
X.21 cabling refers to the cabling between the Site Controller and the X.21 connector on the Junction
Panel.
NOTICE: Either X.21 or E1 cabling is used, depending on which option is ordered.
User Alarms/Controls cabling refer to the cabling between the Site Controller and the connector on the
Junction Panel.
RGPS and GPS cabling refer to the cabling between the Site Controller and the connectors on the
Junction Panel.
NOTICE: X.21 and RGPS cabling depends on ordered configuration.
5.2.1
User Alarms/Controls, X.21, RGPS, and GPS Cabling – MTS LiTE
Table 36: User Alarms/Controls, X.21, RGPS, and GPS Cabling for MTS LiTE
In-
dex
Cable Part
Number
From Unit/ Con-
nection Name
To Unit/ Con-
nection Name
Notes
MTS LiTE with RGPS and E1 or RGPS and X.21
2a
3066546B
09
Junction Panel/
X.21
Site Controller/
X.21/Remote
GPS
15 pin D male connector
type
2b Junction Panel/
RGPS
15 pin D female connector
type
3a
3066549B
03
Junction Panel/
User Alarms/
Controls
Site Controller/
Alarm/Controls
25 pin D female connector
type
3b Door Alarm Molex connector type
MTS LiTE with Internal GPS and X.21
1 3066543B
23
Junction Panel/
GPS
Site Controller/
GPS
Coax cable
2a 3066546B
10
Junction Panel/
X.21
Site Controller/
X.21/Remote
GPS
N/A
3a
3066549B
03
Junction Panel/
User Alarms/
Controls
Site Controller/
Alarm/Controls
25 pin D female connector
type
3b Door Alarm Molex connector type
MTS LiTE with Internal GPS and E1
1 3066543B
23
Junction Panel/
GPS
Site Controller/
GPS
Coax cable
3a
3066549B
03
Junction Panel/
User Alarms/
Controls
Site Controller/
Alarm/Controls
25 pin D female connector
type
6802800U74-AP
Chapter 5: Interconnection and Internal Cabling
170