4.7.5
RX Connection
RX connection between the MTS 4 Prime Cabinet is dependent on the diversity of the MTS 4 Prime
Cabinet.
• For Single diversity, Filter 1 (far left) in the MTS 4 Prime Cabinet is connected to the RX Splitter 1 in
the Expansion Cabinet.
• For Dual diversity, Filter 1 (far left) in the MTS 4 Prime Cabinet is connected to the RX Splitter 1 in
the Expansion Cabinet; Filter 2 (far right) is connected to the RX Splitter 2 in the Expansion
Cabinet.
• For Triple diversity, Filter 1 (far left) in the MTS 4 Prime Cabinet is connected to the RX Splitter 1 in
the Expansion Cabinet; Filter 2 (far right) is connected to the RX Splitter 2 in the Expansion
Cabinet; Filter 3 (in the middle) is connected to the RX Splitter 3 in the Expansion Cabinet.
Figure 64: RX Connection Between MTS 4 Prime Cabinet and MTS4 Expansion Cabinet
FILTER
REAR VIEW
MTS 4 PRIME CABINET
MTS 4
EXPANSION
CABINET
BR1 BR2 BR3 BR4 Exp.
Cabinet
FILTER
REAR VIEW
BR1 BR2 BR3 BR4 Exp.
Cabinet
FILTER
REAR VIEW
BR1 BR2 BR3 BR4 Exp.
Cabinet
RX SPLITTER
REAR VIEW
BR1 BR2 BR3 BR4 Prime
Cab
RX SPLITTER
REAR VIEW
BR1 BR2 BR3 BR4 Prime
Cab
RX SPLITTER
REAR VIEW
BR1 BR2 BR3 BR4 Prime
Cab
NOTICE: Rx connection cables between the MTS 4 Prime Cabinet and the Expansion Cabinet
are routed on the outside of the cabinet, as shown in the Figure below.
6802800U74-AP
Chapter 4: Hardware Installation
134