Figure 25: MTS – Wall Fixing
500
M6
NOTICE: Use brackets and screws appropriate for the site wall properties.
4.5
Electrical Connections
NOTICE:
Battery backup systems are not manufactured by Motorola Solutions. Consult the
manufacturers instruction manual and other pertinent documentation for installing battery
systems. Any local regulations shall be adhered to when installing battery equipment.
The equipment cabinet is shipped with all cabling within the cabinet factory-installed. If
necessary, see Interconnection and Internal Cabling on page 163, for cabling within the cabinet.
After the station equipment mechanical installation, connect the following electrical cables:
•
Grounding Cables
• Power Supply Cables
• Antenna Cables
• GPS Cables
- Remote GPS Receiver Cable
- Internal GPS Cable
• Site Link Cables
• Alarm System Cables
CAUTION: For lightning strikes and surge protection, ground the screens of the shielded cables
and the coax cables and the Ground Box itself and Ground Box Junction in accordance with the
Motorola Standards and Guidelines for Communications Sites, R56 guidelines and national
standards, at the entrance of the building.
NOTICE:
Proper surge protection should be installed on Ethernet/E1/X.21 site links, all antennas, and
power inputs to prevent potential damage to the MTS. For more information, see Surge
Arrestors and Suppliers on page 488.
For full instructions and guidelines, always see
Motorola Standards and Guidelines for
Communications Sites, R56.
6802800U74-AP
Chapter 4: Hardware Installation