Chapter 13: MTS Troubleshooting
378
Alarm ID
Descrip-
tion
Recovery
Action
Clear Ac-
tion
Notes
ALM_TX_CLIP_DE-
TECT_ALM_FAULT
LM_TX_CLIP_DE-
TECT_FAULT
ALM_TX_CLIP_DE-
TECT_ALM_WARN
ALM_TX_CLIP_DE-
TECT_WARN
ALM_TX_TEMP_INTER-
NAL_WARN
ALM_TX_TEMP_INTER-
NAL_FAULT
ALM_PA_TEMP_INTER-
NAL_WARN
ALM_PA_TEMP_INTER-
NAL_FAULT
Reported
when Jave-
lin clip de-
tected fail-
ure condi-
tion still ex-
ists after 1
minute.
Exciter Jav-
elin clip de-
tected.
Internal
Power Am-
plifier tem-
perature is
too high.
Internal
Power Am-
plifier tem-
perature is
too high.
BRC is de-
keyed by the
software.
The output
power is re-
duced by the
software.
The output
power is re-
duced by the
software.
BRC is de-
keyed by the
software.
BRC is re-
keyed by the
software. If
the alarm
condition
disappears
after key-up
then the
alarm is
cleared. If
the alarm is
reported for
the third time
it cannot be
cleared until
next BRC re-
set.
If the alarm
condition
disappears
then the out-
put power is
restored by
the software
to the target
level. If the
alarm is re-
ported for
the third time
it cannot be
cleared until
next reset.
If the alarm
condition
disappears
then the out-
put power is
restored by
the software
to the target
level.
If the alarm
condition
disappears
the alarm is
cleared and
BRC can be
re-keyed
again.
The alarm may
be reported be-
cause of the
BRC hardware
failure or config-
uration prob-
lems.
The alarm may
be reported be-
cause of the
BRC hardware
failure or config-
uration prob-
lems.