Service Manual

226
6802800U74-AN
Chapter 6: Configuration and Testing
If… Then…
If you want to log on to the Test Applica-
tion in the BR-Arch-2 architecture,
In the command line enter the command:
testapp
Postrequisites:
NOTICE: To reset Base Radio and return to the default Base Radio application, type reset
oplatform.
6.2.2
Test Equipment
The following table lists the recommended test equipment for the equipment cabinet procedures.
Equivalent equipment is acceptable.
WARNING: Ensure that the test equipment is connected to the same ground system as the
equipment under test before any other connections are made to the test equipment.
Table 74: Equipment for Cabinet Testing
Equipment Model/Type Manufacturer Description
Service Terminal Locally Pro-
cured
Used to access and inter-
face with Site Controller and
BR MMI
Service Connector
Box
0166502N05 Motorola Sol-
utions
Used for measuring receiver
sensitivity
Basic Service Cable 3066565B01 Motorola Sol-
utions
Coaxial Directional
Coupler
3041-20 Narda Used for receive test signal
injection into duplex TX/RX
antenna port
Circulator, 260 MHz
band
Circulator, 360 MHz–
405 MHz
Circulator, 800 MHz–
900 MHz
Ferrocom
9C30-41 Ferrocom
9C78 Ferrocom
Load 375 BNM Narda
RF Attenuator, 10dB minimum 100 W Motorola Sol-
utions
Used to attenuate transmit
signals for testing
RF Adapter 33 QMA-N-50-
1/133 NE
RF Adapter 31 N-QMA- 1/1- -
NE
RF Adapter 33_716-N-50-1/- - -
_UE
Huber & Suh-
ner
Huber & Suh-
ner
Huber & Suh-
ner
“N” female to “QMA” male
“N” female to “QMA” female
N female to DIN 7-16 male
Rubidium Frequency
Standard
PRFS (or 2008) Ball/Efratom
(UCT)
Used as a frequency stand-
ard for receive test