Service Manual

6802800U74-AN
Chapter 5: Interconnection and Internal Cabling
215
In-
dex
Cable
Part
Number
From Unit / Connection
Name
To Unit / Connection
Notes
Name
2
3066544B
Power Supply Unit1/
Duplexer or Post Filter/
Red cable
06
CAN2
CAN1
3
3066544B
Duplexer or Post Filter/
ATCC 1/ CAN1
Red cable
03
CAN2
4
3066544B
ATCC 1/ CAN2
ATCC 2/ CAN1
Red cable
09
5
3066544B
ATCC 2/ CAN2
Power Supply Unit2/ CAN1
Red cable
06
6
3066575B
Power Supply Unit2/
Site Controller2/ CAN
With redun-
01
CAN2
dant Site
Controller/
red cable
7
0966513A
Power Supply Unit2/
CAN Bus termination
Without re-
01
CAN2
dundant
Site Con-
troller
NOTICE: When MTCCs or HCs are used instead of ATCCs, the CAN Bus is connected directly
from Duplexer or Post Filter/ CAN2 connector to Power Supply Unit2/ CAN1 connector.