Service Manual
209
6802800U74-AN
Chapter 5: Interconnection and Internal Cabling
In-
dex
Cable
Part
Number
From Unit To Unit Notes
bers on
page 188.
18
3066543B
ATCC (3, 4)
Post Filter 2 /
TX path, Post Filter cable routed
16
TX in Prime
through conjunction hole at side
Cabinet
of the cabinet
19
3066543B
RX Splitter 1 /
Duplexer 1/
RX path/ RX on 1 or 2 ant.
11
Prime Cab
Exp Cab (in
MTS 4 Prime
Cabinet)
20
3066543B
RX Splitter 2 /
Duplexer 2 /
RX path/ RX on 1 or 2 ant.
11
Prime Cab
Exp Cab (in
MTS 4 Prime
Cabinet)
21
3066543B
RX Splitter 3 /
Preselector /
RX path/ RX on 2 ant.
11
Prime Cab
Exp Cab (in
MTS 4 Prime
Cabinet)
NOTICE:
In the Prime Cabinet, the cables from ATCC 1/TX OUT to Post Filter 1/TX and from ATCC 2/TX
to Post Filter 2/TX needs to be combined with a T Cable and connected to Post Filter 1/TX,
allowing Expansion Cabinet channels to be connected to Post Filter 2/TX.
When MTCC is used instead of ATCC, connect the cables to corresponding inputs and outputs.
RX cables from Filters in Prime Cabinet to RX Splitters in the Expansion Cabinet are routed
through holes on the back side of the top-lid.