Service Manual
203
6802800U74-AN
Chapter 5: Interconnection and Internal Cabling
In-
dex
Cable
Part
Number
From Unit To Unit Notes
bers on
page 188.
18
3066543B
ATCC (3, 4)
Duplexer 2 /
TX path, Duplexer TX cable rout-
16
TX in Prime
ed through conjunction hole at
Cabinet
side of the cabinet
19
3066543B
RX Splitter 1 /
Duplexer 1/
RX path/ RX on 1 or 2 ant.
11
Prime Cab
Exp Cab (in
MTS 4 Prime
Cabinet)
20
3066543B
RX Splitter 2 /
Duplexer 2 /
RX path/ RX on 1 or 2 ant.
11
Prime Cab
Exp Cab (in
MTS 4 Prime
Cabinet)
21
3066543B
RX Splitter 3 /
Preselector /
RX path/ RX on 2 ant.
11
Prime Cab
Exp Cab (in
MTS 4 Prime
Cabinet)
NOTICE:
In the Prime Cabinet, the cables from ATCC 1/TX OUT to Duplexer 1/TX and from ATCC 2/TX
to Duplexer 2/TX needs to be combined with a T Cable and connected to Duplexer 1/TX,
allowing Expansion Cabinet channels to be connected to Duplexer 2/TX.
When MTCC is used instead of ATCC, connect the cables to corresponding inputs and outputs.
RX cables from Filters in Prime Cabinet to RX Splitters in the Expansion Cabinet are routed
through holes on the back side of the top-lid.