Service Manual
172
6802800U74-AN
Chapter 5: Interconnection and Internal Cabling
5.4.4
Ethernet Site Link Cabling – MTS 4 with Dual Site Controller
Table 47: Ethernet Site Link Cabling for MTS 4 with Dual Site Controller
In-
dex
Cable
Part Num-
ber
From Unit/ Con-
nection Name
To Unit/ Connec-
Notes
tion Name
1
3066544B
01
Base Radio 1 /
SC1
Site Controller1/
BR1
Ethernet link/ Grey cable
2
3066544B
02
Base Radio 2/
SC1
Site Controller1/
BR2
Ethernet link/ Black cable
3
3066544B
04
Base Radio 3/
SC1
Site Controller1/
BR3
Ethernet link/ Grey cable
4
3066544B
05
Base Radio 4/
SC1
Site Controller1/
BR4
Ethernet link/ Black cable
5
3066544B
15
Base Radio 1 /
SC2
Site Controller2/
BR1
Ethernet link/ Grey cable,
only for configuration with
redundant Site Controller
6
3066544B
16
Base Radio 2/
SC2
Site Controller2/
BR2
Ethernet link/ Black cable,
only for configuration with
redundant Site Controller
7
3066544B
01
Base Radio 3/
SC2
Site Controller2/
BR3
Ethernet link/ Grey cable,
only for configuration with
redundant Site Controller
8
3066544B
02
Base Radio 4/
SC2
Site Controller2/
BR4
Ethernet link/ Black cable,
only for configuration with
redundant Site Controller
3066562B
Junction Panel/
RJ45 coupler
Bend Link breakout and in-
01
9
30015009
003
Link1
RJ45 coupler Site Controller1/ Exp
Cab
sert RJ45 coupler.
Ethernet link
3066562B
01
10
Junction Panel/
Link2
RJ45 coupler Bend Link breakout and in-
sert RJ45 coupler.
30015009
002
RJ45 coupler Site Controller2/ Exo
Cab
Ethernet link
3066544B
11 17
3066544B
12 17
Site Controller2/
Red. Out
Site Controller1/
Red. Out
Site Controller1/
Red. In
Site Controller2/
Red. In
Ethernet link/ Blue cable,
only for configuration with
redundant Site Controller
Ethernet link/ Blue cable,
only for configuration with
redundant Site Controller