Service Manual

137
6802800U74-AN
Chapter 4: Hardware Installation
NOTICE: In Table 46: Ethernet Site Link Cabling for MTS 4 with Single Site Controller on
page 169 and Table 47: Ethernet Site Link Cabling for MTS 4 with Dual Site Controller on
page 172; and Figure 102: Ethernet Site Link Cabling for MTS 4 with Single Site
Controller on page 171 and Figure 103: Ethernet Site Link Cabling for MTS 4 with Dual
Site Controller on page 173E1 on old Junction Panel is equivalent to Link1 and AUX on
old Junction Panel is equivalent to Link2.
4.10.1.4
Connecting Ethernet Site Link Retrofit Kit for MTS 4 with Expansion
Cabinet (old JP)
When and where to use:
Follow this procedure to gain Ethernet Site Link functionality from the E1 and AUX connectors on the
previous type of MTS 4 Junction Panel. The procedure applies to an MTS Expansion Cabinet
configuration with single Site Controller.
Procedure:
1 On the MTS Prime Cabinet, remove existing E1 cable from E1 connector on Junction Panel.
2 Connect the open E1 connector on the Junction Panel with the RJ45 coupler (3066562B01).
3 Bend AUX breakout and insert the second RJ45 coupler (3066562B01).
4 Follow Table 48: Ethernet Site Link Cabling for MTS 4 Expansion Cabinet with Single Site
Controller on page 174 and Figure 104: Ethernet Site Link Cabling for MTS 4 Expansion Cabinet
with Single Site Controller on page 175 for further cabling and connections.
4.10.1.5
Connecting Ethernet Site Link Retrofit Kit for MTS 4 with Expansion
Cabinet (new JP)
When and where to use:
Follow this procedure to gain Ethernet Site Link functionality from the Link1 and Link2 connectors on
the newer type of MTS 4 Junction Panel. The procedure applies to an MTS Expansion Cabinet
configuration with single or dual Site Controllers.
Procedure:
1 Bend open and connect the open Link1 connector on the Junction Panel with the RJ45 coupler
(3066562B01).
2 Bend open and connect the open Link2 connector on the Junction Panel with the RJ45 coupler
(3066562B01).
3 Attach remaining cables.
For configurations with single Site Controller, follow Table 48: Ethernet Site Link Cabling for
MTS 4 Expansion Cabinet with Single Site Controller on page 174 and Figure 104: Ethernet
Site Link Cabling for MTS 4 Expansion Cabinet with Single Site Controller on page 175 for
further cabling and connections.
For configurations with dual Site Controller, follow Table 49: Ethernet Site Link Cabling for
MTS 4 Expansion Cabinet with Dual Site Controller on page 175 and Figure 105: Ethernet
Site Link Cabling for MTS 4 Expansion Cabinet with Dual Site Controller on page 177 for
further cabling and connections.