13
4
6802800U74-AN
Chapter 4: Hardware Installation
Figure 78: Site Link Connector X.21 Pinout
Table 25: Site Link Connector X.21 on Junction Panel
Pin No. Function
1 Not Used
2 Tx Data B
3 Control B
4 Rx Data B
5 Indication B
6 Signal Timing B
7 Byte Timing B
8 Ground
9 Tx Data A
10 Control A
11 Rx Data A
12 Indication A
13 Signal Timing A
14 Byte Timing A
15 Not Used
4.10
Ethernet Site Link Cabling
Newer versions of the MTS 2 and MTS 4 Junction Panels contain breakouts for Ethernet Site Link
connectors (labeled as Link1 and Link2). To gain Ethernet site link functionality on these newer
versions of Junction Panel, remove the breakout(s) and insert a RJ45 coupler. For information on
placement on the Junction Panel, see the following figures.
Figure 79: MTS 2 Junction Panel E1/X.21 and Ethernet Site Link Connectors
X.21
E1 Ethernet Site Link