6 Remove the Ribbon cable from the Module cage.
7 Mount the two brackets to the Module cage using 10 pcs. M4 screws.
8 Bend in the area at the back of the Module Cages for Ribbon cables to be routed through later.
Assembling the Module Cage in the MTS 4 Cabinet
Procedure:
1 Remove the Module Cage Beauty Plate (if any).
2 Mount all cables going from the lower Module Cage in your specific configuration and fix them temporarily in the
rack before mounting the air separator shelf and module cage.
Note: This would typically be:
Ethernet cables from Base Radio(s) in lower Module Cage to SC in upper Module Cage (SC2).
Ethernet cables from Base Radio(s) in upper Module Cage to SC in lower Module Cage (SC1).
CAN Bus cables to and from Filters.
3 Assemble the Air Separator shelf above the existing Module Cage using four M6 screws.
4 Assemble the Module Cage extracted from MTS 2 in Extracting the Module Cage from MTS 2 on page 398.
Note: For more information regarding assembling of a module cage in the MTS 4 Cabinet, see Adding
Additional Module Cage to MTS 4.
5 Connect the power supply cables and optional backup battery cables.
6 Connect the Ethernet cables and CAN Bus cables mounted in Step 2 above.
7 Switch ON the Power Supply Unit.
8 Check the LED indicators to verify the PSU is operating correctly.