User's Manual

Table Of Contents
3066544B17 Redundant CTRL signal
cable
SC1 / RedOut SC2 / RedIn
Note: Make sure to follow the color indications on both the cables as well as on the Site
CONTROLLER.
11 Remove the Terminator from the CAN2 output on the Power Supply Unit and connect the CAN Bus cable
according to the scheme below:
Part no Cable type From To
3066544B03 CAN Bus cable SC2 / CAN PSU2 / CAN2
12 Connect the power cables to the MTS Power Supply Units.
Configuring Redundant Site Controller
Note: Redundant Site Controller feature is supported by MTS Software releases:
MTS SPU R5.2_002.34 or later
MTS SPU R6.0_001.12 or later
Note: On power up of the Standby Site Controller the Base Radios may dekey and reset. Base Radios will
automatically recover and key up again within 20 seconds.
Process:
1 Perform Site Controller Hardware Pre-Checks.
See Performing Site Controller Hardware Pre-Checks on page 392.
2 Configure the Site Controller Configuration Files.
See Configuring Site Controller Configuration Files on page 393.
3 Configure Ethernet ports connecting the two Site Controllers.
See Configuring Ethernet Ports on page 393.
4 Configure the ID values of the Site Controllers.
See Configuring Site Controller IDs on page 394.
Performing Site Controller Hardware Pre-Checks
Procedure:
1 Ensure that both Site Controllers are correctly installed and are running identical software applications, Boot
images and configuration files.
2 In order for the Redundant Site Controller feature to work correctly, the Site Controller and BR Boot1 version
must be:
TSC_RLJ_BOOT1–R06.40.07 or later for SC.
BRC_RLJ_BOOT1–R06.40.05 or later for Base Radio.
Note: The Boot1 version can be checked on the Site Controller and BRs by resetting the Site
Controller/BR and interrupting the startup sequence when prompted to go into Boot1 mode. The
software version is displayed when entering Boot1 mode.
3 Check that the redundant Site Controller Ethernet Link cables are connected correctly, as shown in Cable
Connections.
4 Proceed to Configuring Site Controller Configuration Files on page 393 below.
392 | Expansion Options
Send Feedback | September 2014 | 6802800U74-AD
Applicant: Motorola Solutions
Equipment Type: ABZ89FC5827 / 109AB-5827
Exhibit D2