User's Manual
Table Of Contents
- 5827 Exhibit D - User Information
- Tune-Up Procedure
- User Manual
- MANUAL COVER PAGE
- Copyrights
- CMM Labeling and Disclosure Table
- Service Information
- Document History
- Contents
- List of Figures
- List of Tables
- List of Processes
- List of Procedures
- About MTS LiTE, MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
- MTS Overview
- General Safety
- Radio Frequency Distribution System
- RFDS Theory of Operation
- MTS LiTE and MTS 2 RFDS
- MTS 4 RFDS
- Expansion Cabinet RFDS
- Site Controller
- XHUB Controller
- Base Radio
- Power Supply Unit
- Cooling Fans
- Technical Specifications
- Environmental and Standards Specifications
- Cabinet and Module Specifications
- MTS Cabinets Frequency Range
- Dimensions of the MTS Cabinets
- RF Specifications
- Transmitter Specifications
- Receiver Specifications
- Site Controller Specifications
- Internal GPS Module Input Specifications
- MTS LiTE / MTS 2 Duplexer Specifications
- MTS LiTE / MTS 2 Preselector Specifications
- MTS 4 Duplexer Specifications
- MTS 4 Post Filter Specifications
- MTS 4 Preselector Specifications
- Auto Tune Cavity Combiner (ATCC) Specifications
- Manual Tune Cavity Combiner (MTCC) Specifications
- Hybrid Combiner Specifications
- Base Radio Specifications
- Power Supply Unit Specifications
- XHUB Controller Specifications
- RX Splitter Specifications
- MTS LiTE, MTS 2, and MTS 4 Connectors
- Expansion Options
- MTS 4 Outdoor Enclosure
- Appendix A: Field Replaceable Units (FRUs)
- Appendix B: Planned Maintenance Inspection (PMI)
- Appendix C: Static Precautions and ESD Strap
- Appendix D: TETRA/Dimetra Acronyms
Chapter
14
Technical Specifications
Environmental and Standards Specifications
This section presents the Environmental Specifications and the Standards Specifications.
Environmental Specifications
Table 102: Environmental Specifications
Environmental Specifi-
cations
Description
Operating temperature
• MTS LiTE 400 MHz (without fans) -30 °C to 55 °C
• MTS LiTE 400 MHz (with fans) -30 °C to 60 °C
• MTS LiTE 800 MHz (always fans) -30 °C to 60 °C
•
MTS 2 400 MHz (without fans) -30 °C to 55 °C
• MTS 2 400 MHz (with fans) -30 °C to 60 °C
• MTS 2 260 MHz (without fans) -30 °C to 55 °C
• MTS 2 800 MHz (always fans) -30 °C to 60 °C
• MTS 2 900 MHz (always fans) -30 °C to 60 °C
• MTS 4 400 MHz (with fans) -30 °C to 60 °C
• MTS 4 400 MHz (without fans) -30 °C to 55 °C
• MTS 4 260 MHz (always fans) -30 °C to 60 °C
• MTS 4 800 MHz (with fans) -30 °C to 55 °C
Storage temperature -40 °C to 85 °C
Humidity 5% to 95% non-condensing for 30 C. EN 300 019 1-3 Class 3.2
Operational altitude -300 m to 3000 m
Environmental protection IP 20 according to IEC 60529
Operating in use Shock: EN300 019-2-3 T 3.2
Vibration: EN300 019-2-3 T 3.2
Storage and Transportation
• Weather protected, not temperature-controlled storage locations. ETSI EN
300 019-1-1 Class 1.2, and EN 300 019-2-1 T1.2
• ETSI EN 300 019-1-2 Class2.3 public transportation, and EN 300
019-2-2 T2.3.
357 | Technical Specifications
6802800U74-AD | September 2014 | Send Feedback
Applicant: Motorola Solutions
Equipment Type: ABZ89FC5827 / 109AB-5827
Exhibit D2