User's Manual

Table Of Contents
LED LED/Port Name Position Controlled By Indication
LED19
Prime Cab
Port 8 LED1 OFF: Ethernet link not present
GREEN: Ethernet link present
Port 8 LED2 OFF: Ethernet activity not present
YELLOW: Ethernet activity present
XHUB Controller – Front Panel Switches
The following table lists the Front Panel switches of the XHUB Controller and their functions.
Table 82: XHUB Controller – Front Panel Switches
Switch Name Switch Function
Reset The front-panel switch can be used to initiate a Hard Reset of
the XHUB Controller. Push and hold (>3 seconds) for Hard
Reset.
XHUB Controller – Front Panel Connectors
The following table lists the front panel connectors of the XHUB controller.
Table 83: XHUB Controller – Front Panel Connectors
Connector Name Connector Type To/From Comment
Power MOLEX (2 Pin) PSU 28.5 V DC
BR RJ45 BR
Ethernet
AUX1 RJ45 BR or Ethernet Sitelink Used in E-Tetra configura-
tions or Ethernet Sitelink
AUX2 RJ45 BR Used in E-Tetra configura-
tions
Service RJ45 Service Terminal Provides service access
Prime Cab RJ45 SC (in Prime Cab)
XHUB Controller – Rear Panel
This section provides information about Rear Panel connectors of the XHUB Controller.
XHUB Controller – Rear Panel Connectors
The following table lists the rear panel connectors of the XHUB controller.
Table 84: XHUB Controller – Rear Panel Connectors
Connector Name Connector Type To/From Comment
Alarms/Control IDE 34-pin Cabinet door sensor Provide Alarm
284 | XHUB Controller
Send Feedback | September 2014 | 6802800U74-AD
Applicant: Motorola Solutions
Equipment Type: ABZ89FC5827 / 109AB-5827
Exhibit D2