Figure 31: Warning Label on Hot Modules
Warning: DC input voltage must be no higher than 60 VDC. This maximum voltage includes
consideration of the battery charging "float voltage" associated with the intended supply system, regardless
of the marked power rating of the equipment. Failure to follow this guideline may result in electric shock.
Warning: RF energy burn hazard: disconnect power in the cabinet to prevent injury while disconnecting
and connecting antennas.
Caution: All Tx and Rx RF cables outer shields must be grounded per Motorola Standards and Guidelines
for Communications Sites manual requirements.
Caution: All Tx and Rx RF cables must be connected to a surge protection device according to the
Motorola Standards and Guidelines for Communications Sites manual. Do not connect Tx and Rx RF
cables directly to an outside antenna.
Important: All equipment must be serviced by Motorola-trained personnel.
GTR 8000 Base Radio Supplemental Safety Installation Requirements
The Supplemental Safety and Installation Requirements include the following:
The GTR 8000 Base Radio must be installed in a suitable, in-building enclosure. A restricted access location is
required when installing this equipment into the end system.
The base radio contains a Class 1 built-in power supply component. This component is equipped with an
appliance inlet for connecting to an AC input, as well as DC input terminals which meet SELV DC circuit
requirements.
When installing the equipment, all requirements of relevant standards and local electrical codes must be fulfilled.
The maximum operating ambient temperature of this equipment is 60 °C. The maximum operating altitude is 3000
meters above sea level.
The 28.6 VDC output from the power supply to the PA is at an energy hazard level (exceeds 240 VA). When
installing into the end system, care must be taken so as not to touch the output wires.
When the base radio is used in a DC reverting system, the DC power supply must be located in the same building
as the base radio, and it must meet the requirements of a SELV circuit.
DC Mains Grounding Connections
Caution: This equipment is designed to permit the connection of the earthed conductor of the DC supply
circuit to the earthing conductor at the equipment. If this connection is made, you must meet all following
conditions:
Connect this equipment directly to the DC supply system earthing electrode conductor or to a bonding jumper
from an earthing terminal bar or bus in which the DC supply system earthing electrode conductor is connected.
Locate this equipment in the same immediate area (such as adjacent cabinets) as any other equipment that has a
connection between the earthed conductor of the same DC supply circuit and the earthing conductor (and also the
point of earthing of the DC system). Do not earth the DC system elsewhere.