User's Manual
AP_CMM2 User Manual Issue 4 Draft Pa
g
e 25 of 48
- Passwords can be from 1 to 16 characters. Any combination of characters
is allowed, except for these special characters: “ , . ‘ { } / \ ; : [ ] ( ) ` ~
- NOTE: If the operator forgets either the password or the IP address for
the module, a Canopy default plug can be used to regain access. For
details, see the section on the default plug under Interface Screens.
- There are two types of passwords that can be configured: display-only or
full-access. The display-only password allows the operator to view the
module’s current status. The full-access password allows the operator to
view the module’s current status and change its configuration. By viewing
the red lettering to the right of the entry fields, the operator can tell that a
password is set, but can’t see the password.
• The operator can enter information about the Site Name, Location, and Contact. This
is optional.
CONFIGURATION OF THE CLUSTER MANAGEMENT MODULE
The operator will need to verify the following when configuring a Cluster Management Module:
• What type of power will the module use, AC or DC?
• If using AC power, there is a switch to choose 115V or 230V on the
power transformer. This switch must be set correctly before power is
applied, or the unit may be damaged. See the schematic inside the
Cluster Management Module for further information.
115/230 V switch
AC power
connectors
Fuse receptacle
Figure 7: Location of 115/230 V Switch
• The AC power connectors are labeled
- N for Neutral
- L for Line
- PE for Protective Earth (PE) (ground)
• The maximum thickness wire to be used is 12 AWG (4 mm
2
).
INSTALLATION OF THE EQUIPMENT
The following tools may be needed during installation:
• 3/8” nut driver