User's Manual
Backhaul User Manual Draft for Regulatory Review
Pa
g
e 10 of 55
PRODUCT DESCRIPTION
Canopy Backhaul
Backhaul links provide point-to-point connectivity either as a standalone link or feeding an Access
Point cluster as part of a Canopy network.
Backhaul modules are available in 2.4, 5.2, and 5.7 bands and in both 10 and 20 Mbps. 2.4 and
5.7 backhauls can be used with reflectors on either or both ends. Regular 5.2 backhauls cannot be
used with reflectors in the US or Canada due to regulatory agency restrictions. Extended Range
(ER) 5.2 Backhauls have very low transmit power and it is recommended to use reflectors at both
ends.
The following table shows typical ranges for each type of backhaul.
Module Type Modulation Rate Reflectors Typical Range
5200 BH10 (DES)
5201 BH10 (AES)
10 None allowed in US or
Canada
2 miles (3.2 km)
5200 BH10 ER (DES)
5201 BH10 ER (AES)
10 One end 2 miles (3.2 km)
5200 BH10 ER (DES)
5201 BH10 ER (AES)
10 Both ends 10 miles (16 km)
5200 BH20 ER 20 One end 1 mile (1.6 km)
5200 BH20 ER 20 Both ends 5 miles (8 km)
5700 BH10 (DES)
5701 BH10 (AES)
10 None 2 miles (3.2 km)
5700 BH10 (DES)
5701 BH10 (AES)
10 One end 10 miles (16 km)
5700 BH10 (DES)
5701 BH10 (AES)
10 Both ends 35 miles (56 km)
5700 BH20 20 None 1 mile (1.6 km)
5700 BH20 20 One end 5 miles (8 km)
5700 BH20 20 Both ends 35 miles (56 km)
2400 BH10 (DES)
2401 BH10 (AES)
10 None 5 miles (8 km)
2400 BH10 (DES)
2401 BH10 (AES)
10 One end 15 miles (24 km)
2400 BH10 (DES)
2401 BH10 (AES)
10 Both ends 35 miles (56 km)
2400 BH20 20 None 3 miles (4.8 km)
2400 BH20 20 One end 5 miles (8 km)
2400 BH20 20 Both ends 35 miles (56 km)
When using Backhauls in standalone links, the type of Backhaul is selected based on RF
environment, throughput, and range needed. When using Backhauls in a network and co-locating a
BH with Access Points, the type of backhaul is usually selected based on having the BH in a
different band than the APs. In other words, if the APs are 5700s, the BH could be a 5200 or a
2400. If the APs are 2400s, the BH could be a 5200 or a 5700. While distance separation of 100
vertical feet (30 m) on a tower can allow co-locating APs and BHs from the same band, choosing
cross-band APs and BHs is usually the better choice.