User's Manual

68P8100XYXX-O APRIL 2003 3-21
PRELIMINARY
Internal Review (First Draft - 50% to 60% Complete)
SIMULCAST CONFIGURATION ILLEGAL CARRIER DETERMINATION AND BASE RADIO MEASUREMENT
SOURCE OF THE TRANSMITTER METERING POINTS
Table 3-4 lists each of the transmitter metering points and where the measurement is taken.
CHECKING THE TRANSMITTER FREQUENCY
Perform Procedure 3-5 to measure the transmitter frequency of a base radio.
T
ABLE 3-4 SOURCE FOR THE TRANSMITTER METERING POINTS
Current Column Read From
Station Forward Power (Watts) Individual base radio
Station Reflected Power (Watts) Individual base radio
Station VSWR Individual base radio
RFDS VSWR Power monitor in the RFDS
P
ROCEDURE 3-5 HOW TO CHECK THE TRANSMITTER FREQUENCY
1 Turn off the STR 3000 Simulcast Base Radio using the On and Off switch on the
front of the power supply module.
CAUTION
Make sure power to the base radio is OFF. Connecting or
disconnecting RF cables while the transmitter is keyed
could cause personal injury or equipment damage from RF
arcing.
NOTE
If two STR 3000 Simulcast Base Radio rack transmitters are
combined together, turn off all of the base radios in both racks.
2 Disconnect the transmit cable from the base radio.
3 Connect the transmit port to the service monitor.
4 Set the service monitor to monitor the transmit frequency of the base radio being
tested.
5 Turn on the base radio being checked using the On and Off switch on the front of
the power supply module and allow the station to fully initialize.
6 Use the CSS application to read the configuration from the base radio.
See “Reading the Configuration File from a Device” in the STR 3000 Simulcast
Base Radio online help.
Exhibit 9E