User's Manual

50 68P80801H45-1 1/20/2002
Troubleshooting EBTS System Manual - Vol 2
QUAD Base Radio Station Verification Procedures
NOTE
Future versions of the QUAD BR will ship with
software that recognizes the BR cabinet position.
Default Motorola Manufacturing BR programmed
cabinet position is (0,0), which automatically sends the
radio to Test Application software mode upon power
up. Upon setting a valid cabinet position, the radio
will default to the Call Processing mode of operation..
4. Collect revision numbers from the station by typing the
following command:
5. If all modules return revision numbers of the format “Rxx.xx.xx”, then all
revision numbers are present. In that case, verification requires no further
action. If revision numbers return as blank, or not in the format “Rxx.xx.xx”,
contact your local Motorola representative or Technical Support.
6. Set desired cabinet id, position, and of BR by typing the following
commands, with the final number on each command being the desired
cabinet id and position. The command example below sets cabinet id to 5,
and cabinet position to 2.
7. After checking all BRs, log out by keying the following command:
NOTE
To start Call Processing mode of operation, reset the
Base Radio using the front panel switch.
> login -u eld
password: motorola
eld>
eld> fv -oplatform
eld>
eld> ci -oplatform -c5
eld> pi -oplatform -p2
eld>
eld> logout