User's Manual
68P80801H45-1 1/20/2002 47
EBTS System Manual - Vol 2 Troubleshooting
QUAD Channel Base Radio/Base Radio FRU Replacement Procedures
QUAD BRs Radio FRU Replacement Procedure
Perform the following steps to replace any of the Base Radio FRUs:
NOTE
After a Control Board or BR replacement, the
integrated Site Controller (iSC) reboots the BR.
Whenever the BR goes off-line, the Replacement BRC
Accept Timer begins counting down. A BR reboot
occurs if the BR remains off-line as the timer times out.
(The timer’s default period is three minutes.) If
someone turns on the BR before the timer times out,
power down the BR. Then wait for the minimum
timer period before turning on the BR.
1. Notice the Power Supply rocker switch, behind the front panel of the Power
Supply. Set the Power Supply rocker switch to the OFF (0) position. Turning
off this switch removes power from the Base Radio.
2. Loosen the front panel fasteners. These are located on each side of the
module being replaced.
3. Pull out the module.
4. Insert the non-defective replacement module by aligning the module side
rails with the appropriate rail guides inside the Base Radio chassis.
5. Gently push the replacement module completely into the Base Radio chassis
assembly using the module handle(s).
CAUTION
DO NOT slam or force the module into the chassis
assembly. Rough handling can damage the connectors
or backplane.
6. Secure the replacement module by tightening the front panel fasteners to the
specified torque of 5 in-lbs.
7. Apply power to the Base Radio by setting the switch to the ON position.
8. Perform the Station Verification Procedure.