User's Manual
68P80801E35-B 5/1/2002 17
EBTS System Manual - Vol 2 Troubleshooting
Generation 2 Single Channel BR Station Verification Procedures
program on the service computer, log onto the BR. Bold type indicates user
input commands.
2. Set the Frequency of the R2660 to 810MHz. Power out should be set to
–80 dBm.
3. Set the channel frequency.
4. Verify the R2660 signal level:
5. The resulting output will look similar to this:
>login –ufield
>password: motorola
field>
field> freq -orxch1 -f810
field> enable -orxch1 -dbr1 -son
field> ppc -orxch1 -mchn -s1
field> ppr -orxch1 -r1 -a50
field> ppr -orxch1 -r1 -a100
SGC Atten.(dBm)=0.000000
Freq. Offset=-15.059323
Sync. Attempts=1.000000
Sync. Successes=1.000000
BER%=0.000000
RX Path1 RSSI=-80.934021
RX Path2 RSSI=-127.012520
RX Path3 RSSI=-127.012520
Chn sig. strength=-57.098698
Chn intf. strength=-91.696739
field>