User's Manual

6 68P80801E35-B 5/1/2002
Base Radio Controllers EBTS System Manual - Vol 2
Enhanced Base Radio Controller
Enhanced Base Radio Controller Controls and Indicators
The EBRC monitors the functions of other Base Radio modules. The LEDs on the
front panel indicate the status of EBRC-monitored modules. The CTL LED on the
front panel light momentarily on initial BR power-up and on BR resets. Figure 2
shows the front panel of the EBRC.
Indicators
Table 3 lists and describes the EBRC LEDs.
Table 3 EBRC Indicators
LED Color Module
Monitored
Condition Indications
BR Green BR Solid (on) Station is keyed
Flashing (on) Station is not keyed
Off Station is out of service or power is
removed
PS Red Power
Supply
Solid (on) FRU failure indication - Power Supply
has a major alarm and is out of service
Flashing (on) Power Supply has a minor alarm and
may be operating at reduced
performance
Off Power Supply under normal operation
(no alarms)
EX Red Exciter Solid (on) FRU failure indication - Exciter has a
major alarm and is out of service
Flashing (on) Exciter has a minor alarm and may be
operating at reduced performance
Off Exciter under normal operation
(no alarms)
PA Red Power
Amplifier
Solid (on) FRU failure indication - PA has a major
alarm and is out of service
Flashing (on) PA has a minor alarm and may be
operating at reduced performance
Off PA under normal operation (no
alarms)
EBTS316g
06701SJW
ENHANCED CONTROL
RESETBR PS EX PA CTL R1 R2 R3
SERVICE ACCESS
Figure 2 EBRC (Front View)