EBTS System Manual - Vol 2 Base Radio Controllers
Enhanced Base Radio Controller
Determining FRU and Kit Revisions
For Generation 2 BR/EBRC
These commands will return all available FRU and Kit Revision numbers. Use
these to determine installation requirements:
1. Connect one end of the RS-232 cable to the service computer.
2. Connect the other end of the RS-232 cable to the Service Access port, located
on the front panel of the EBRC module.
3. Power on the BR using the front switch on the Power Supply Module. Press
the reset button on the Control Module front panel. At the prompt, hit a
Carriage Return on the service computer to enter the test application mode.
Using the password motorola, log in to the BR.
4. Collect revision numbers from the station by typing the
following command:
5. If all modules return revision numbers of the format “Rxx.xx.xx”, then all
revision numbers are present. In that case, verification requires no further
action. If revision numbers return as blank, or not in the format “Rxx.xx.xx”,
contact your local Motorola representative or Technical Support.
For Legacy Single Channel BR/BRC
1. Connect one end of the RS-232 cable to the service computer.
2. Connect the other end of the RS-232 cable to the STATUS port, located on the
front panel of the BRC.
3. Using the field password, login to the BR.
:> login -ufield
password: motorola
eld>
eld> fv -oplatform
eld>