User's Manual

6 68P80801E35-B 5/1/2002
Base Radio EBTS System Manual - Vol 2
Generation 2 Single Channel 800 MHz Base Radio Overview
For Legacy Single Channel BR/BRC
1. Connect one end of the RS-232 cable to the service computer.
2. Connect the other end of the RS-232 cable to the STATUS port, located on the
front panel of the BRC.
3. Using the field password, login to the BR.
4. Collect revision numbers from the station by typing the
following commands:
BRC>dekey
BRC>test_mode
BRC>get brc_rev_no
BRC>get rx1_rev_no
BRC>get rx2_rev_no
BRC>get rx3_rev_no
(
if BR is 3 branch
)
BRC>get pa_rev_no
BRC>get ex_rev_no
BRC>