User's Manual

68P80801E35-A 9/1/2001 13
EBTS System Manual - Vol 2 Troubleshooting
Generation 2 Single Channel BR Station Verification Procedures
3.2 Enable the channel by setting a data pattern to “iden”
NOTE
After the following command is entered, power will
be transmitted at the output of the Power Amplier.
3.3 Set the transmit power to 40 watts and key the BR.
4. After keying the Base Radio, verify the forward and reected powers of the
station along with the station VSWR with the parameters listed in Table 2.
NOTE
The reported value for forward power is not indicative
of Base Radio performance. This value is reported
from the internal wattmeter. These limits are only for
verication of operation and are not representative of
true operating power of the transmitter.
Table 2 Generation 2 BR Transmitter Parameters
Parameter Value or Range
Forward Power Greater than 36 Watts
Reected Power Less than 2.0 Watts
VSWR Less than 1.6:1
eld> dpm -otxch1 -miden
eld> ptm -otx_all -mdnlk_framed
eld> power -otxch1 -p40