EN RAP50 USER / INSTALLER MANUAL v2.1 REV.
00. CONTENT 01. SAFETY INSTRUCTIONS INDEX ATTENTION: 01. SAFETY INSTRUCTIONS This product is certified in accordance with European Community (EC) safety standards. 1B 02.
01. SAFETY INSTRUCTIONS GENERAL WARNINGS • This manual contains very important safety and usage information. Read all instructions carefully before beginning the installation/ usage procedures and keep this manual in a safe place that it can be consulted whenever necessary. • This product is intended for use only as described in this manual. Any other enforcement or operation that is not mentioned is expressly prohibited, as it may damage the product and put people at risk causing serious injuries.
01. SAFETY INSTRUCTIONS September 2009. • Attach the permanent label for the manual release as close as possible to the release mechanism. • Disconnect means, such as a switch or circuit breaker on the electrical panel, must be provided on the product’s fixed power supply leads in accordance with the installation rules. • If the product to be installed requires power supply of 230Vac or 110Vac, ensure that connection is to an electrical panel with ground connection.
02. THE PRODUCT 02. THE PRODUCT RAP50 DESCRIPTION The RAP50 is a small microwave radar ideal for glass and pedestrian doors, and can be installed up to 4m high. It has long-distance technology for unidirectional detection of people or objects. • Connector • Cover TECHNICAL CHARACTERISTICS • Power supply 12-30 Vdc, 12-24Vac • Detection method • DIP switches Microwave Technology • Maximum installation height 4.
03. INSTALLATION INSTALLATION AND CONNECTIONS To guarantee the correct functioning of the RAP50, pay attention to the following instructions: • • • • • Disconnect the power during installation as it may damage the device or cause damage to its functioning; Avoid moving objects near the detector; Avoid heavy rain and snow; Install in a place where there is no vibration; Avoid fluorescent light sources. 1 2 4 1 2 3 DRILLING Attach the mounting mold and drill the fixing holes (3.
04. CONFIGURATION 04. CONFIGURATION DIP SWITCH SETTINGS PRESENCE TIMER Time ON Dip switch #1, #2, #3 e #4 ON 1s (factory set) 1 2 3 4 5 1 2 3 4 5 ON 3s A ORIENTATION DETECTION ON This setting is used to define the orientation of the flow direction of people or objects.
05. PROGRAMMING 05. PROGRAMMING DETECTION AREA ADJUSTMENT WIDTH ADJUSTMENT Adjust the detection module up or down to determine how close the detection area is to the door. 90° Adjust the detection module to the left or right to obtain the desired side detection area. 37° 01 • Rotate the sensor module in the direction of the arrow while holding the module support with the other hand. 41° 02 • Remove the upper part of the sensor towards you.
06. TROUBLESHOOTING INSTRUCTIONS FOR CONSUMERS AND SPECIALIZED TECHNICIANS FAILURE CAUSE / RESOLUTION No LED on • There is no current supplying the device; • The device is defective (send to technical services). The door is detected • Tilt the sensor housing out of the door; • Lower the sensitivity setting; Object is detected too late • Increase sensitivity.