User guide

PRODUCT INSTALLATION
14 eng
12 VOLT BATTERY CONNECTION
a - Power cable
b - 50 amp manual reset
circuit breaker
c - Jumper wire (not
supplied)
d - Common ground
1. Install a 50 amp manual reset circuit breaker in line with the
positive lead.
2. Connect the red battery lead from the power cable circuit
breaker to the positive (+) battery post.
3. Connect the black battery lead from the power cable to the
negative (–) battery post.
RED
BLK
a
b
c
d
37289