Service manual

8. Personality Transfer
8. 1 Introduction
Due to the different variations of the (OEM looks) of the personal cellular
telephones, each main board must be configured correctly to ensure that the
unit takes on the correct personality required. Therefore, when a main board
is replaced its personality must be transferred into the new board, so that it
functions correctly in the customers unit. There are two possible methods of
transfer:
·Normal Transfer,and:
·Master Transfer.
If the defective unit powers up, then the Normal Transfer method should be
followed. If the faulty unit will not power up, then a Master transfer will be
required to configure the replacement board, once installed.
8. 2Normal Transfer
This method allows the personality, selected features and stored phone
numbers of a defective radio, to be transferred into a repaired radio. Data is
transferred from the donor unit into the recipient unit using a Transfer card
(Part No 5104025D01).The instruction steps should be followed in order.
Step 1: Insert the Transfer card into the slot located on the back of the donor
unit.Turn the donor unit on, the display should showClone.
Step 2: The donor unit is now in the cloning mode, and ready to transfer the
first block of data.
Step 3: Enter 021# via the units keypad.This command will cause the first
block of information to be uploaded into the Transfer card.
Step 4: While data transfer is taking place between the unit and the card,
Please wait will be displayed. After a short period of time, if the data transfer
has been completed correctly, Clonewill re-appear in the donor units display.
Step 5: When the first data block has been successfully uploaded, remove
the card from the donor.
Step 6: Insert the Transfer card into the slot located on the back of the
recipient unit. Turn the recipient unit on, the display should show Clone.
Step 7: The recipient unit is now in the cloning mode, and ready to receive
the first block of data.
Step 8: Enter 03# via the units keypad. This command will cause the
recipient unit to download the first data block from the Transfer card.
Step 9: While data transfer is taking place between the card and the unit,
Please wait will be displayed. After a short period of time, if the data transfer
has been completed correctly, Clonewill re-appear in the recipient units
display.
Step 10: The second data block must now be transferred. Repeat steps 1 to
9, but enter 022# to program the second data block into the Transfer card.
Step 11: The third data block ( known as table5#) must now be transferred.
Repeat steps 1 to 9, but enter 025# to program the third data block into the
Transfer card.