Control Engineering, Inc.Universal Serial Network User Guide
Table Of Contents
- Motion Control Engineering, Inc. 11380 White Rock Road Rancho Cordova, CA 95742 voice 916 463 9200 fax 916 463 9201 www.mceinc.com
- User Guide, Universal Serial Network
- Important Precautions and Useful Information
- Safety and Other Symbol Meanings
- In This Manual
- USN Installation
- IMC, PTC, PHC Installation
- Mounting the Board Assemblies
- 1. Determine an appropriate location for the USN-BASE assembly. (Preferred location is in the upper left quadrant of the control enclosure.)
- 2. Mount the board, facing outward, such that access to critical controller components is not blocked.
- 3. For PTC/PHC programmable controllers, mount the M2C assembly near the USN-BASE assembly. (For a duplex, mount an M2C assembly in each controller enclosure but just one USN-BASE assembly in the enclosure of your choice.)
- 1. Determine an appropriate location for the USN-BASE assembly. (Preferred location is in the upper left quadrant of the control enclosure.)
- Mounting the Board Assemblies
- Motion 3000ES Installation
- USN Power Connection, Elevators
- Power Connection, Escalators
- IMC, PTC, PHC Installation
- Configuration
- Device Type
- 1. Set only the F7 switch UP.
- 2. Press N until Device Type is displayed.
- 3. Press S to select. Supported Device Types are:
- 4. Select the Device Type.
- 5. Press N to go to save menu. Press S to save.
- 6. After the device type has changed, place the F7 switch down.
- 7. Reset the USN board by pressing the RSTA button.
- 8. After the device reboots, confirm new device type is selected.
- 1. Set only the F7 switch UP.
- Escalator Only
- IP Setup
- Device Type
- Communication Connections
- IMC
- 1. Connect the external Ethernet cable to Ethernet Port A on the USN-BASE assembly.
- 2. Connect the supplied C-RJ11/DB9M cable from a controller MC-RS (serial board) COM port to RS232 Port B (J7) on the USN-BASE assembly.
- 3. Through the controller MPU board, set the connected COM port to media= serial and device= PC.
- 4. On the MC-RS board, set the connected COM port slide switch to DCE.
- 5. Press RSTA to reset the USN board so that it will read its new connections.
- 1. Connect to the group controller using a CRT, terminal emulator, or TigerTerm software.
- 2. Press F1, then 1 to get to the General configuration screen.
- 3. Access the ICOM setting. Set it to the COM port connected to the MC-USN board. For example, if the MC- USN board is connected to COM2 on the MC-RS board, set the ICOM setting to COM2.
- 4. Save.
- 5. With the Function Switch F8 switch UP (all others down), press N to cycle through the menu to verify that information is correct.
- 1. Connect the external Ethernet cable to Ethernet Port A on the USN-BASE assembly.
- PTC/PHC
- 1. Connect the external Ethernet cable to Ethernet Port A on the USN-BASE assembly.
- 2. The boards in the controller are connected along a ribbon cable bus. Connect the M2C assembly’s “From PCA” (JP3) to the last controller board on the bus using supplied ribbon cable.
- 3. Connect the M2C assembly’s CAN2 port to the “Internal Network” (J5) connector on the USN-BASE assembly using the C-RJ-11 cable .
- 4. For Duplex, connect both CAN2 ports on the M2C assembly to supplied splitter. Then plug the splitter into “Internal Network” (J5) connector on USN-BASE assembly.
- 5. Press RSTA to reset the USN board so that it will read its new connections.
- 6. With the Function Switch F8 switch UP (all others down), press N to cycle through the menu to verify that information is correct.
- 1. Connect the external Ethernet cable to Ethernet Port A on the USN-BASE assembly.
- Motion 3000ES
- IMC
- MC USN Information
- Security Password Default for IMC Connections
- KCE Functionality

Copyright
© 2008, Motion Control Engineering. All Rights Reserved.
This document may not be reproduced, electronically or mechanically, in whole or in part, without
written permission from Motion Control Engineering.
Trademarks
All trademarks or registered product names appearing in this document are the exclusive property
of the respective owners.
Warning and Disclaimer
Although every effort has been made to make this document as complete and accurate as possible,
Motion Control Engineering and the document authors, publishers, distributors, and
representatives have neither liability nor responsibility for any loss or damage arising from
information contained in this document or from informational errors or omissions. Information
contained in this document shall not be deemed to constitute a commitment to provide service,
equipment, or software by Motion Control Engineering or the document authors, publishers,
distributors, or representatives.
Limited Warranty
Motion Control Engineering (manufacturer) warrants its products for a period of 15 months from
the date of shipment from its factory to be free from defects in workmanship and materials. Any
defect appearing more than 15 months from the date of shipment from the factory shall be
deemed to be due to ordinary wear and tear. Manufacturer, however, assumes no risk or liability for
results of the use of the products purchased from it, including, but without limiting the generality
of the forgoing: (1) The use in combination with any electrical or electronic components, circuits,
systems, assemblies or any other material or equipment (2) Unsuitability of this product for use in
any circuit, assembly or environment. Purchasers’ rights under this warranty shall consist solely of
requiring the manufacturer to repair, or in manufacturer's sole discretion, replace free of charge,
F.O.B. factory, any defective items received at said factory within the said 15 months and
determined by manufacturer to be defective. The giving of or failure to give any advice or
recommendation by manufacturer shall not constitute any warranty by or impose any liability upon
the manufacturer. This warranty constitutes the sole and exclusive remedy of the purchaser and
the exclusive liability of the manufacturer, AND IN LIEU OF ANY AND ALL OTHER WARRANTIES,
EXPRESSED, IMPLIED, OR STATUTORY AS TO MERCHANTABILITY, FITNESS, FOR PURPOSE SOLD,
DESCRIPTION, QUALITY PRODUCTIVENESS OR ANY OTHER MATTER. In no event will the
manufacturer be liable for special or consequential damages or for delay in performance of this
warranty.
Products that are not manufactured by MCE (such as drives, CRTs, modems, printers, etc.) are not
covered under the above warranty terms. MCE, however, extends the same warranty terms that
the original manufacturer of such equipment provide with their product (refer to the warranty
terms for such products in their respective manual).