SDS
SHIDA BATTERY TECHNOLOGY CO., LTD. 
Safety Data Sheet 
Date of Issue: 12-Feb-2015         File No.: SD-SDS-2015-07A 
Page 2 of 7 
This  sheet  is  provided  as  technical  information  only.  The  information  and  recommendations  set  forth  are  made  in  good  faith  and 
believed to be accurate as of the date of preparation. SHIDA BATTERY TECHNOLOGY CO., LTD make no warranty, expressed or 
implied, with respect to this information and disclaims all liabilities from reliance on it. 
 Inhalation of a large number of vapors or fumes released due to heat may cause respiratory. 
  Ingestion 
 Ingestion of battery contents may cause mouth, throat and intestinal burns and damage. 
Unknown Toxicity 
 No information available. 
3.  Composition/ Information on Ingredients 
Chemical Name  Molecular formula  CAS No.  Concentration% 
Lithium Cobalt Oxide  CoLiO2  12190-79-3  30~40 
Aluminum  Al  7429-90-5  <10 
Aluminum foil  Al  7429-90-5  5~15 
Lithium hexafluorophosphate  LiP6  21324-40-3  10~20 
Copper  Cu  7440-50-8  10~20 
Graphite  C  7782-42-5  15~25 
PVDF  (C2H2F2)n  24937-79-9  <10 
4. First Aid Measures 
General Advice 
First aid is Applicable only in the case of cell rupture. 
Skin Contact: 
Washing immediately  with  plenty of  water and soap  for at  least 15  minutes.  In  the  case  of skin  irritation  or 
allergic reaction see a physician. 
Eye contact: 
If symptoms persist, call a physician. Rinse immediately with plenty of water, also under the eyelids, for at least 
15  minutes.  Keep  eye  wide  open  while  rinsing.  Remove  contact  lenses,  if  present  and  easy  to  do.  Continue 
rinsing. Do not rub affected area. 
Inhalation of Vented Gas: 
Remove  to  fresh  air.  If  symptoms  persist,  call  a  physician.  Get  medical  attention  immediately  if  symptoms 
occur. 
Ingestion: 
Do not induce vomiting. Rinse mouth immediately and drink plenty of water. Call a physician or poison control 
center immediately. 
Most important symptoms and effects, both acute and delayed 
Contact with internal components may cause allergic skin sensitizations (rash) and irritate eyes, 
nose, throat, respiratory system. Cobalt and cobalt compounds are considered to be possible 
human carcinogen(s). 
Indication of any immediate medical attention and special treatment needed 
No information available 
5.  Fire –Fighting Measures 
Suitable Extinguishing Media 
Use foam , dry powder or dry sand, CO
2
 as appropriate. 
Unsuitable Extinguishing Media: 