POWER RATINGS
* Stand-By three-phase power (LTP) 6.5 kVA (5.2 kW) / 400V / 9.4A
* PRP three-phase power 5.7 kVA (4.6 kW) / 400V / 8.2A
* PRP single-phase power 4 kVA / 230V / 17.4A
* COP single-phase power /
Frequency 50 Hz
Cos j 0.8
4 STROKE OHV, NATURAL ASPIRATED
Model YANMAR L100N
* Stand-By net power 6.5 kWm (8.8 hp)
* PRP net power 5.7 kWm (7.7 hp)
* COP net power /
Cylinders / Displacement 1 / 435 cm³
Bore / Stroke 86 / 75 (mm)
Compression ratio 20 : 1
BMEP (Brake Mean Eective
Pressure : LTP - PRP)
/
Speed governor type Mechanical
FUEL CONSUMPTION
110 % (Stand-by power) 1.5 lt./h
100 % to PRP 1.3 lt./h
75 % to PRP 1 lt./h
50 % to PRP 0.8 lt./h
COOLING SYSTEM Air
Total system cap. - only engine /
Fan air flow /
LUBRIFICATION SYSTEM
Total oil system capacity /
Oil capacity in sump 1.6 lt.
Oil consumption at full load /
EnginE 3000 rpm
EXHAUST SYSTEM
Maximum exhaust gas flow /
Max. exhaust gas temp. /
Maximum back pressure 4.3 kPa
External diameter exhaust pipe /
ELECTRICAL SYSTEM 12 Vdc (AE)
Starter motor power 0.8 kW
Battery charging alternator cap. 15 A
Cold start 0°C
With cold start aid /
AIR FILTER Dry
Combustion air flow /
HEAT REJECTED AT FULL LOAD
To exhaust system /
To water and oil /
Radiated to room /
To charge cooler /
* Output powers according to ISO 8528-1
air cooled diesel
manual recoil
* Output powers according to ISO 3046-1
DEFINITION
Valid declared powers up to the followings environmental conditions: temperature
25°C, altitude 100 meters above sea level
LTP power: stand-by power: Maximum available power for use with variable loads for a
yearly number of hours limited at 500 h. No overload is admitted.
PRP power: continue power with variable loads. Maximum power for use with variable
loads for a yearly illimited nubers of hours.
COP power: continuous power with constant load. Maximum power for use with constant
loads for a yearly unlimited numbers of hours.
three-phase
power
FEATURES
Manual recoil (AA)
Low oil pressure automatic engine shut down
Sockets: 1x 400V 16A 3P+N+T CEE
1x 230V 16A 2P+T CEE
1x 230V 16A 2P+T Schuko
Circuit breaker
Fuel level gauge
Protective frame and partially covered
Meets EC directives for the safety
AVR version on request
Electric Starter on request (AE)
pag 1