Product Manual
The generating set GE 7554 is a unit which transforms the mechanical energy, generated by endothermic engine, into electric
energy, through an alternator.
Is meant for industrial and professional use, powered by an endothermic engine; it is composed of various main parts such as:
engine, alternator, electric and electronic controls, the fairing or a protective structure.
The assembling is made on a steel structure, on which are provided elastic support which must damp the vibrations and also
eliminate sounds which would produce noise.
Technical data GE 7554 YSX
A.C. GENERATOR
Three-phase generation 7 kVA (5.6 kW) / 400 V / 10 A
Three-phase generation 6 kVA (4.8 kW) / 400 V / 8.7 A
Single-phase generation 5 kVA / 230 V / 21.7 A
Frequency 50 Hz
Power factor (cos ϕ) 0.8
ALTERNATOR self-excited, self-regulated
Type Three-phase, synchronous
Insulating class H
ENGINE
Mark / Model YANMAR / L 100 N
Type / Cooling system Diesel 4-Stroke / Air
Displacement / Cylinders 406 cm
3
/1
Output 6.5 kW (8.8 HP)
Speed 3000 rpm
Engine oil capacity 1.6 l
Fuel consuption (75% of PRP) 1.2 l/h
Starter Electric
GENERAL SPECIFICATIONS
Battery 12V - 38Ah
Fuel tank capacity 23 l
Running time (75%) 19 h
Protection IP 54
Dimensions max. Lxwxh * 1020x645x930
Weight (dry) * 245Kg
Measured acustic power 91 LWA (66 dB(A) - 7 m)
Guaranteed acustic power 92 LWA (67 dB(A) - 7 m)
* Dimensions and weight are inclusive of all parts without wheels and towbar.
01/06/11 35649-GB
TECHNICAL DATA GE 7554 YSX
M
1.5
© MOSA REV.0-01/06
2000 / 14 / CE
2000 / 14 / CE
OUTPUT
Declared power according to ISO 8528/1 (temperature 25°C, 30% relative hummidity, altitude 100 m above sea level).
It’s admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION: The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specic precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level (LWA) - Measure Unit dB(A): it stands for acoustic noise released in a certain delay of time. This is not
submitted to the distance of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A): it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(LWA) of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A) Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A) Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE: the symbol when with acoustic noise values, indicates that the device respects noise emission limits
according to 2000/14/CE directive.