STANDARD
EQUIPMENT
Diesel
engine
Air cooling Electric
Starter
Battery
12V
Oil pressure
Indicator
Battery char-
ge indicator
Hours-meter
Synchronous
alternator
Compound Sockets Sockets ELCB-GFI Circuit breaker Thermal
shut o
Voltmeter
GENERATING SET
GE 12000 KD/GS
GE12000KD-GSZGB 07/15
Technical data GE 12000 KD/GS
A.C. GENERATION - 50 Hz - Three-phase synchronous alternator, self-excited, self-regulated
* Stand-by three-phase power
* PRP three-phase power
* PRP single-phase power
Cos j
Insulation class
12 kVA (9.6 kW) / 400 V / 17.3 A
11 kVA (8.8 kW) / 400 V / 15.9 A
6 kVA / 230 V / 26 A
0.8
H
* Output powers according to ISO 8528-1
ENGINE - 4-stroke diesel, direct injection, Air cooling
Model
* Stand-By net power
* PRP net power
Cylinders/ Displacement
Speed
Fuel consumption (75% of PRP)
KOHLER KD 425/2
11.5 kW (15.6 HP)
10.5 kW (14.3 HP)
2/ 851 cm³
3000 rpm
2.2 l/h
* Powers according to ISO 3046-1
GENERAL SPECIFICATIONS
Tank capacity
Running time (75% of PRP)
IP protection degree
*Dimensions Lxlxh (mm)
*Dry weight
**Acoustic power LwA (pressure LpA)
18 l
8.2 h
IP 23
1000x610x715
162 kg
99 dB(A) (74 dB(A) @ 7m)
* Dimensions and weight without trolley/trailer. / ** For fixed installation only in the EU market
VERSIONS ON
REQUEST
Engine version with oil bath air filter and engine shutdown for low oil level and high temperature.
OPTIONS ON
REQUEST
Earthing kit Trolley CTM10
FEATURES
 Electric starter
 Sockets: 1x400V 32A 3P+N+T CEE - 1x230V 32A 2P+T CEE
1x230V 16A 2P+T Schuko
 ELCB-GFI (Ground Fault Interruptor)
 Circuit breaker
 Protective frame
 Meets EC directives