8 kva Honda Three Phase Petrol Auto Start Generator GE SX-8000 HBT
13/11/14 M38_EN
ENGLISH
ENGLISH
USE OF THE REMOTE CONTROL TCM 15
The coupling of the TCM 15 with the generating set, permits to
work far from the set itself.
The remote control is connected to the front plate, with a mul-
tiple connector.
The TCM 15 assures the following fonctions:
- starting (starting key Q1)
- stop (starting key Q1)
- choke control (L6)
PUSH AND
SCREW TIGHT
OFF
START
ON
Q1
OFF
O1
TCM 6
PUSH AND
SCREW TIGHT
MAKE SURE
When the TCM 15 - 6 is used, it is not possible to connect the E.A.S automatic intervention unit.
!
USE OF THE REMOTE CONTROL TCM 6
The coupling of the TCM 6 with the generating set, ready for
remot starting, permits to work far from the set itself.
The remote control is connected to the front plate, and/or rear
plate, with a multiple connector.
The TCM 6 assures the following fonctions:
- starting (starting key Q1)
- stop (starting key Q1)
- indication of oil low pressure (warning light O1)
To stop the set turn the key to the position "OFF".
OFF
OFF
START
ON
Q1
TCM 15
L6
CHOKE
M
38.5
REMOTE CONTROL
TCM 15 - 6
REV.1-07/11
N.B.: the position of the selector LOCAL START/REMOTE
START (l6) on the generating sets must be on the position
"REMOTE START".
29