User Manual

GE 12000 KSX/GS
GE 12000 KSX/GS - AVR
M
1.5
REV.0-04/14
Technical data and machine description
08/04/1435931-GB
ThegeneratingsetGE12000isaunitwhichtransformsthemechanicalenergy,generatedbyendothermicengine,intoelectric
energy,throughanalternator.
Ismeantforindustrialandprofessionaluse,poweredbyanendothermicengine;itiscomposedofvariousmainpartssuchas:
engine,alternator,electricandelectroniccontrols,thefairingoraprotectivestructure.
Theassemblingismadeonasteelstructure,onwhichareprovidedelasticsupportwhichmustdampthevibrationsandalso
eliminatesoundswhichwouldproducenoise.
Technical data GE 12000 KSX/GS GE 12000 KSX/GS - AVR
A.C. GENERATOR
Stand-by single-phase power 13.5kVA(12.1kW)/230V/58.7A
PRP single-phase power 12kVA(10.8kW)/230V/52.5A
Stand-by single-phase power 13.5kVA(12.1kW)/115V/117.4A
PRP single-phase power 12kVA(10.8kW)/115V/104.3A
Frequency 50Hz
Cos ϕ 0.9
ALTERNATOR
Type synchronous,single-phase,self-excited,self-regulated,brushless
Insulating class H
ENGINE
Mark / Model KOHLERKD477/2
Type / Cooling system Diesel4Stroke/air
Cylinders / Displacement 2/954cm
3
Stand-by output 14.9kW(20.3HP)
P.R.P. output 13.5kW(18.4HP)
Speed 3000rpm
Fuel consumption (75% of PRP) 2.8l/h
Engine oil capacity 3l
Starter Electric
GENERAL SPECIFICATIONS
Tank capacity
23l
Running time (75% of PRP) 8.2h
Protection IP23
Dimensions / max. Lxwxh (mm) * 1320x790x750
Weight on base* 297Kg
Measured acoustic power LwA (pressure LpA) 96db(A)(71db(A)@7m)
Garanteed acoustic power LwA (pressure LpA) 96db(A)(71db(A)@7m)
 *Dimensionsandweightareinclusiveofallparts
OUTPUT
DeclaredpoweraccordingtoISO8528-1(temperature25°C,30%relativehumidity,altitude100mabovesealevel).
(*Stand-by)=maximumavailablepowerforuseatvariableloadsforayearlynumberofhourslimitedat500h.Nooverloadis
admitted.
(**PrimepowerPRP)=maximumavailablepowerforuseatvariableloadsforayearlyillimitednumberofhours.Theaverage
powertobetakenduringaperiodof24hmustnotbeover80%ofthePRP.
It’sadmittedoverloadof10%eachhourevery12h.
Inanapproximativewayonereduces:of1%every100maltitudeandof2.5%forevery5°Cabove25°C.
ACOUSTIC POWER LEVEL
ATTENTION:Theconcreteriskduetothemachinedependsontheconditionsinwhichitisused.Therefore,itisuptotheend-
userandunderhisdirectresponsibilitytomakeacorrectevaluationofthesameriskandtoadoptspecicprecautions(for
instance,adoptingaI.P.D.-IndividualProtectionDevice)
Acoustic Noise Level (LWA) - Measure Unit dB(A): itstandsforacousticnoisereleasedinacertaindelayoftime.Thisisnot
submittedtothedistanceofmeasurement.
Acoustic Pressure (Lp)- Measure Unit dB(A): itmeasuresthepressureoriginatedbysoundwavesemission.Itsvaluechanges
inproportiontothedistanceofmeasurement.
Theherebelowtableshowsexamplesofacousticpressure(Lp)atdifferentdistancesfromamachinewithAcousticNoiseLevel
(LWA)of95dB(A)
Lpa1meter=95dB(A)-8dB(A)=87dB(A) Lpa7meters=95dB(A)-25dB(A)=70dB(A)
Lpa4meters=95dB(A)-20dB(A)=75dB(A) Lpa10meters=95dB(A)-28dB(A)=67dB(A)
PLEASE NOTE:thesymbolwhen withacousticnoise values,indicatesthat thedevicerespects noiseemissionlimits
accordingto2000/14/CEdirective.
2000 / 14 / CE
2000 / 14 / CE