User Manual
TROUBLE-SHOOTING GE 10000 / 12000 KD/GS
GE 10000 / 12000 KD/GS-D
M
40.2
REV.0-03/14
Themotordoesnotstartup,or
startsupandthenstopsimme-
diately
1) Lackoffuelintankorfueltapclosed
2) Fuellterclogged
3) Airleaksinfuelsystem
4) Batterynotactivated,loworfaulty
5) Batterycableterminalslooseorcorroded
6) Othercauses
1) Rellthetank.Openthefueltap
2) Replace
3) Checkthefeedingcircuit
4) Activate,recharge,orreplacethebattery
5) Tightenandclean.Replaceifcorroded.
6) ConsultthemotorOperatingManual.
Problem Possiblecause Solution
ENGINE
1)Airorfuellterclogged
2) Overload
1) Cleanorreplacelterelement(s).
Refertoenginemanual
2) Checktheconnectedloadsandifrecessaryreduce
Themotordoesnotaccelerate.
Inconstantspeed.
Too little power provided by
motor.
Otherproblemsorinconvenien-
cesontheengine
ConsultthemotorOperatingManual.
27/03/14 25950-GB
WARNING
!
● Havequaliedpersonneldomaintenanceandtroubleshootingwork.
● Stoptheenginebeforedoinganyworkinsidethemachine.Ifforanyreasonthemachinemustbeoperatedwhileworkinginside,pay
attentionmovingparts,hotparts(exhaustmanifoldandmufer,etc.)electricalpartswhichmaybeunprotectedwhenthemachineis
open.
● Removeguardsonlywhennecessarytoperformmaintenance,andreplacethemwhenthemaintenancerequiringtheirremovaliscom-
plete.
● Usesuitabletoolsandclothes
● Donotmodifythecomponentsifnotauthorized.
-Seepag.M1.1-
GENERATOR
1) Protectiontrippedduetooverload
2) Differentialprotectiondevicetripped
3) Protectiondevicesdefective
4) Alternatornotsparked
5) Alternatordefective
1) Checktheloadconnectedanddiminish
2) Checkontheentireinstallation:cables,connections,
utilitiesconnectedhavenodefectivesheathingwhich
maycauseincorrectcurrentstoground
3) Replace
4) Carryoutexternalsparktestasindicatedinalternator
manual.AskforinterventionofServiceDepartment
5) Checkwinding,diodes,etc.onalternator(Referto
alternatormanual).Repairorreplace.
AskforinterventionofServiceDepartment
1) Checkpositionofacceleratorlever.
Regulatespeedtoitsnominalno-loadvalue
2) Checkwinding,diodes,etc.onalternator(Referto
alternatormanual).Repairorreplace.
AskforinterventionofServiceDepartment
1) Checktheloadconnectedanddiminish
2) Reduceorrephaseload
3) Checkwinding,diodes,etc.onalternator(Referto
alternatormanual).Repairorreplace.
AskforinterventionofServiceDepartment
1) Checkelectricalconnectionsandtighten
2) AskforinterventionofServiceDepartment
3) Checkwinding,diodes,etc.onalternator(Referto
alternatormanual).Repairorreplace.
AskforinterventionofServiceDepartment
Corrected no-load voltage too
lowwithload
1) Incorrectmotorrunningspeed
2) Alternatordefective
1) Incorrectmotorrunningspeedduetoover-
load
2) Loadwithcosϕlessthanthenominalone.
3) Alternatordefective
Absenceofoutputvoltage
No-load voltage too low or too
high
1) Contactsmalfunctioning
2) Irregularrotationofmotor
3) Alternatordefective
Unstabletension