User Manual

TROUBLE-SHOOTING GE 10000 / 12000 KD/GS
GE 10000 / 12000 KD/GS-D
M
40.2
REV.0-03/14
Themotordoesnotstartup,or
startsupandthenstopsimme-
diately
1) Lackoffuelintankorfueltapclosed
2) Fuellterclogged
3) Airleaksinfuelsystem
4) Batterynotactivated,loworfaulty
5) Batterycableterminalslooseorcorroded
6) Othercauses
1) Rellthetank.Openthefueltap
2) Replace
3) Checkthefeedingcircuit
4) Activate,recharge,orreplacethebattery
5) Tightenandclean.Replaceifcorroded.
6) ConsultthemotorOperatingManual.
Problem Possiblecause Solution
ENGINE
1)Airorfuellterclogged
2) Overload
1) Cleanorreplacelterelement(s).
Refertoenginemanual
2) Checktheconnectedloadsandifrecessaryreduce
Themotordoesnotaccelerate.
Inconstantspeed.
Too little power provided by
motor.
Otherproblemsorinconvenien-
cesontheengine
ConsultthemotorOperatingManual.
27/03/14 25950-GB
WARNING
!
Havequaliedpersonneldomaintenanceandtroubleshootingwork.
● Stoptheenginebeforedoinganyworkinsidethemachine.Ifforanyreasonthemachinemustbeoperatedwhileworkinginside,pay
attentionmovingparts,hotparts(exhaustmanifoldandmufer,etc.)electricalpartswhichmaybeunprotectedwhenthemachineis
open.
● Removeguardsonlywhennecessarytoperformmaintenance,andreplacethemwhenthemaintenancerequiringtheirremovaliscom-
plete.
● Usesuitabletoolsandclothes
● Donotmodifythecomponentsifnotauthorized.
-Seepag.M1.1-
GENERATOR
1) Protectiontrippedduetooverload
2) Differentialprotectiondevicetripped
3) Protectiondevicesdefective
4) Alternatornotsparked
5) Alternatordefective
1) Checktheloadconnectedanddiminish
2) Checkontheentireinstallation:cables,connections,
utilitiesconnectedhavenodefectivesheathingwhich
maycauseincorrectcurrentstoground
3) Replace
4) Carryoutexternalsparktestasindicatedinalternator
manual.AskforinterventionofServiceDepartment
5) Checkwinding,diodes,etc.onalternator(Referto
alternatormanual).Repairorreplace.
AskforinterventionofServiceDepartment
1) Checkpositionofacceleratorlever.
Regulatespeedtoitsnominalno-loadvalue
2) Checkwinding,diodes,etc.onalternator(Referto
alternatormanual).Repairorreplace.
AskforinterventionofServiceDepartment
1) Checktheloadconnectedanddiminish
2) Reduceorrephaseload
3) Checkwinding,diodes,etc.onalternator(Referto
alternatormanual).Repairorreplace.
AskforinterventionofServiceDepartment
1) Checkelectricalconnectionsandtighten
2) AskforinterventionofServiceDepartment
3) Checkwinding,diodes,etc.onalternator(Referto
alternatormanual).Repairorreplace.
AskforinterventionofServiceDepartment
Corrected no-load voltage too
lowwithload
1) Incorrectmotorrunningspeed
2) Alternatordefective
1) Incorrectmotorrunningspeedduetoover-
load
2) Loadwithcosϕlessthanthenominalone.
3) Alternatordefective
Absenceofoutputvoltage
No-load voltage too low or too
high
1) Contactsmalfunctioning
2) Irregularrotationofmotor
3) Alternatordefective
Unstabletension