User Manual

Set-up for operation GE 7000-7500 HSX
M
25
© MOSA REV.0-09/08
01/09/08 35770-GB
BATTERY WITHOUT MAINTENANCE
The included battery must be activated.
To activate it (fill the included acid) please follow the
instructions shown on the manual attached to the
battery. When battery is activated,
DON’T add any
other liquid.
Oil fill tap / dip-stick
Upper oil level
RECOMMENDED OIL
MOSA recommends selecting AGIP engine oil.
Refer to the label on the motor for the recommended
products.
LUBRICANT
Please refer to the motor operating manual for the
recommended viscosity.
MOTORS WITH OIL ALERT DEVICE
The “Oil Alert” system is designed to prevent damage
to the motor due to an insufficient quantity of oil in
the cup. This system automatically shuts off the
motor before the oil level falls below the safety limit.
If the motor does not start up again after shutting
itself off, check the oil level.
FUEL
Gasoline is highly flammable. Refuel with
motor shut off in a flat surfaced well-
ventilated area. Do not refuel in the
presence of flames. Avoid spilling fuel.
Any eventual spilled fuel and fumes are
flammable. Clean any dispersions of fuel
before starting up the motor.
WARNING
Fill the tank with gasoline for automobiles (preferably
lead free or with low lead content in order to reduce
deposits in the combustion chamber to a minimum).
Stop the generating set as soon as possible whenever
the low fuel level warning light (M1) is lighted (if
mounted on the group) and make the refueling.
If the engine doesn’t start after the stop, and the
warning light is lighted during the starting, it means
that there is a lack of fuel in the tank.
For further details on the type of gasoline to use, see
the motor operating manual supplied.
Do not fill the tank completely; leave a space of
approx. 10 mm between the fuel level and the wall of
the tank to allow for expansion.
To check the oil level:
1. Remove the oil-fill tap (24) and clean the dip-stick
(23).
2. Insert the dip-stick into the oil filler without screwing
it in.
3. If the oil level is low, fill with recommended oil up
to the top of the oil filler using the syringe supplied.
AIR FILTER
GROUNDING CONNECTION
The grounding connection to an earthed installation
is obligatory for all models equipped with a
differential switch (circuit breaker). In these groups
the generator star point is generally connected to
the machine’s earthing; by employing the TN or TT
distribution system, the differential switch guarantees
protection against indirect contacts.
In the case of powering complex installations requiring
or employing additional electrical protection devices,
the coordination between the protection devices must
be verified.
For the grounding connection, use the terminal (12);
comply to local and/or current regulations in force
for electrical installations and safety.
It is dangerous to fill the motor with too much oil, as
its combustion can provoke a sudden increase in
rotation speed.
ATTENTION
Check that the dry air filter is correctly installed and
that there are no leaks around the filter which could
lead to infiltrations of non-filtered air to the inside of
the motor.