5 kVA Honda DC Arc Welder Generator Manual
29/11/19 C1UN7020_EN
ENGLISH
ENGLISH
M
1.5
TECHNICAL DATA
REV.0-10/20
GENERATOR GM 5-200 HBM GM 7-200 HBT
Three-phase power max --- 7 kVA (5.6 kW) / 400 V / 10.1 A
Three-phase power PRP --- 6.5 kVA (5.2 kW) / 400 V / 9.4 A
Single-phase power max 5 kVA (kW) / 230 V / 21.7 A ---
Single-phase power PRP 4 kVA (kW) / 230 V / 17.4 A 4 kVA / 230 V / 17.4 A
Single-phase power max 2.5 kVA (kW) / 115 V / 21.7 A ---
Single-phase power PRP 2 kVA (kW) / 115 V / 17.4 A ---
Frequence 50 Hz
ALTERNATOR Self-excited, self-regulated
Type Single-phase, synchronous Three-phase, synchronous
Insulating class H
ENGINE
Mark / Model HONDA GX 390 (STAGE V)
Type / Cooling system Gasoline OHV 4-Stroke / Air
Cylinders / Displacement 1 / 389 cm
3
Net power Stand-by 8.2 kW (11.1 HP)
*Power 3000 rpm
Fuel consumption (Welding 60%) 2.1 l/h
Engine oil capacity 1.1 l
Starter Recoil
* Maximum output (not overloadable) according to SAE J 1349
GENERAL SPECIFICATIONS
Fuel tank capacity 6.1 l
Running time (Welding 60%) 2.9 h
Protection IP 23
*Dimensions max. Lxwxh 870x525x613
*Weight (dry) 97 Kg 100 Kg
Measured acoustic power LwA (pressure LpA) 97 dB(A) (71 dB(A) @ 7m)
Guaranteed acoustic power LwA (pressure LpA) 97 dB(A) (71 dB(A) @ 7m)
* Dimensions and weight are inclusive of all parts without wheels and towbar.
POWER
Declared power according to ISO 3046-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
It’s admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION: The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specic precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level (LWA) - Measure Unit dB(A): it stands for acoustic noise released in a certain delay of time. This is not
submitted to the distance of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A): it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(LWA) of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A) Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A) Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE: the symbol when with acoustic noise values, indicates that the device respects noise emission limits
according to 2000/14/CE directive.
2000 /14/CE
2000 /14/CE