5 kVA Honda DC Arc Welder Generator Manual

31/07/18 Manutenzione Periodica Honda_EN
ENGLISH
ENGLISH
MAINTENANCE SCHEDULE Each Use
First Month or
20 Hrs
Every 3 Months
or 50 Hrs
Every 6 Months
or 100 Hrs
Every Year or
300 Hrs
Check level engine oil
Change engine oil
Check level reduction case oil (applicable types)
Change reduction case oil (applicable types)
Change air cleaner
Clean air cleaner ●*
Replace air cleaner ●**
Clean sediment cup
Check-adjust spark plug
Replace spark plug
Clean spark arrester (applicable types)
Check-adjust idle speed
Check-adjust valve clearance
Clean combustion chamber After every 1000 Hrs.
Clean fuel tank and lter
Check fuel tube Every 2 years (Replace if necessary)
* ● Internal vent carburetor with dual element type only.
● Cyclone type every 6 months or 150 hours.
MAINTENANCE SCHEDULED
HONDA
REV.0-07/18
IMPORTANT
The engine and alternator manufacturers indicate specic maintenance and control intervals: it is obligatory to consult the
books, OPERATION AND MAINTENANCE of the engine and alternator provided with the generator you are using.
If such documents are not supplied with the generator set, ask for a copy to the customer service.
+
The information given in the table is only indicative. Specic instructions are given in the operation manuals.