8 kVA Kohler 250A Three Phase Multi Process DC Arc Welder Generator Product Card

MADE IN ITALY
language
TS 275 EVO MULTI4
auxiliary gEnEration
OUTPUT 1
Type of source Three-phase
Frequency 50Hz
Power kVA (Power kW) Max 8 kVA (6.4kW)
Cos j 0.8
Voltage 400V
Current 11.5 A
OUTPUT 3
Type of source Single-Phase
Frequency 50Hz
Power kVA (Power kW) Max 2.5 kVA/kW
Cos j 0.8/1
Voltage 110V CTE
Current 22.7A
OUTPUT 2
Type of source Single-Phase
Frequency 50Hz
Power kVA (Power kW) Max 5 kVA/kW
Cos j 0.8/1
Voltage 230V
Current 21.7A
OUTPUT 4
Type of source Single-Phase
Frequency 50Hz
Power kVA (Power kW) Max 5 kVA/kW
Cos j 1
Voltage 48V
Current 104A
GENERATION AND
CONTROL PANEL
Dierential switch (400V / 230V)
Magnetothermic switch for 230V sockets
Thermal cut-os for socket protection: 1x 16A for 230V 16A 2P + T CEE
socket
Output sockets: 1x 400V 32A 3P+N+T CEE
1x 230V 32A 2P+T CEE
1x 230V 16A 2P+T CEE
N ° 2 200A output terminals (for 48V)
Earth terminal (PE)
Dierential switch (400V / 230V)
Magnetothermic switch for 230V sockets
Magnetothermic switch for 110V sockets
Thermal cut-os for protection 1x 16A sockets for 110V 16A 2P + T CEE
socket
Output sockets: 1x 400V 32A 3P+N+T CEE
1x 230V 32A 2P+T CEE
1x 110V 32A 2P+T CEE
1x 110V 16A 2P+T CEE
Earth terminal (PE)
Dierential switch (400V / 230V)
Magnetothermic switch for 230V sockets
Output sockets: 1x 400V 32A 3P+N+T IP67 AUS
1x 230V 32A 2P+T IP67 AUS
1x 230V 15A 2P+T IP67 AUS
Earth terminal (PE)
gEnEration (VErs. 400V / 230V / 48V)
gEnEration (VErs. 400V / 230V / 110V)
gEnEration (VErs. aus)
Controller RGK420SA
Thermal circuit breaker for motor protection: 1x30A
Thermal circuit breaker for motor protection: 1x5A
Acoustic signal
Emergency stop button
EnginE Control panEl
RGK420SA CONTROLLER FEATURES
Operating modes
MAN - REMOTE
Display
Backlit display, LCD
Buttons: START -
Key
Generator measurements
Voltage L1-L2 / L2-L3 / L3-L1 - N-L1/N-L2/N-L3
Frequency Hz
Engine measurements Fuel level
Engine revs
Hour meter
Battery voltage
Generator protections
Overvoltage
Under tension
Overfrequency
Underfrequency
Motor protections
Overspeed
Low speed
High temperature
Low oil pressure
Low fuel pre-alarm
Low fuel level
Battery voltage
Inecient battery
Battery charge alternator fault
Emergency stop
Failure to start
Failure to stop
Maintenance
Features
Operator interface with symbols, codes and
texts
Panel or PC programming
External start and stop
Programmable inputs and outputs
Operating temperature: -30 ° C - + 70 ° C
NFC interface for wireless programming
pag 3