14 kVA Kohler Three Phase Multi Process DC Arc Welder Generator Product Card

MADE IN ITALY
language
ENGINE DRIVEN WELDER
TS 405 EVO MULTI4
The images are for reference
water
cooled
diesel electric
starter
4 STROKE, NATURAL ASPIRATED
Model KOHLER KDW1003
Stand-by net power 17.15 kW (23.3 hp)
PRP net power 15.6 kW (21.2 hp)
COP net power /
Cylinder / Dislacement 3 / 1028 cm³ (1.028 lt.)
Bore / Stroke 75 / 77.6 (mm)
Compression ratio 22.8 :1
BMEP (Brake Mean Eective
Pressure : LTP - PRP)
/
Speed governor type Mechanical
FUEL CONSUMPTION
110 % (Stand-by power) 5.4 lt./h
100 % of PRP 4.9 lt./h
75 % of PRP 3.7 lt./h
50 % of PRP 2.7 lt./h
COOLING SYSTEM
Total system cap. - only engine /
Fan air flow 93 m³/min.
LUBRIFICATION SYSTEM
Total oil system capacity 2.6 lt.
Oil capacity in sump 2.5 lt
Oil consumption at full load /
EnginE 3000 rpm
EXHAUST SYSTEM
Maximum exhaust gas flow 3.2 m³/mim.
Max. exhaust gas temp. 540 °C
Maximum back pressure 8000 kPa (0.08 bar)
External diameter exhaust pipe /
ELECTRICAL SYSTEM 12 Vdc
Starter motor power 1.6 kW
Battery charging alternator cap. 40 A
Cold start - 15 °C
With cold start device /
AIR FILTER Dry
Combustion air flow 1.6 m³/min.
HEAT REJECTED AT FULL LOAD
To exhaust system /
To water and oil /
Radiated to room /
To charge cooler /
WELDING PROCESS
SMAW Shielded
Metal Arc welding
(STICK)
Gas Tungsten Arc
Welding (TIG)
GMAW Gas Metal
Arc Welding (MIG)
FCAW Flux Cored
Arc Welding (FLUX
CORED)
Arc Gouging
SMAW (STICK)
pag 1
09/2021
CARATTERISTICHE
Multi-process DC arc welder
“EVO MULTI4” welding control panel
Digital adjustment of the welding parameters
Welding arc adjustment and multi-process parameters
Ammeter and digital welding voltmeter with pre-setting
of the welding parameters
VRD function
AC power generator three-phase and single-phase
available during the welding phase
Digital engine management and control module
Bunded base
Canopy with wide opening to allow easy maintenance
(replacement of air, oil, fuel filters)
Large capacity tank
Fuel level sensor
External plugs for oil and water drainage
Emergency stop button
Central lifting eye
Compliant with EC / EU Directives
E
N
G
I
N
E
S
T
A
G
E
5