14 kVA Kohler Three Phase Multi Process DC Arc Welder Generator_Manual

21/04/21 C1KS1021_EN
ENGLISH
ENGLISH
C.V. WELDING (Constant Voltage) CONSTANT VOLTAGE - GMAW WIRE (MIG) - FCAW CORED WIRE (FLUX CORED)
Welding current 40A / 16V ÷ 400A / 20V
Welding voltage Continue 15V - 45V
Service 330A / 30.5V - 60%
300A / 29V - 100%
OUTPUT CARACTERISTIC C.V. (Constant Voltage)
0
10
20
30
40
50
050100 150200 250300 350400 45
0
I2 (A)
NEMA MIG V=45VMAX V=15Vmin V=25 V=35V
M
1.6.1
TECHNICAL DATA
REV.0-08/21
SIMULTANEOUS UTILIZATION FACTORS
In case of WELDING and GENERATION can be used simultaneously, however, the engine cannot be overloaded. The table
below givesthe maximum limits to be respected.
WELDING CURRENT ≥ 200A 175A 150A 125A 100A 50A
THREE-PHASE POWER 400V cos ϕ 0.8 0 kVA 2.5 kVA 4 kVA 6 kVA 7.5 kVA 11 kVA
SINGLE-PHASE POWER 230V cos ϕ 0.8 0 kVA 2.5 kVA 4 kVA 5 kVA 6 kVA 8 kVA
WELDING CURRENT ≥ 200A 175A 150A 125A 100A 50A
THREE-PHASE POWER 400V cos ϕ 1 0 kW 5 kW 8 kW 10 kW 11 kW 11 kW
SINGLE-PHASE POWER 230V cos ϕ 1 0 kW 2.5 kW 4 kW 5 kW 6 kW 8 kW
SINGLE-PHASE POWER 230V cos ϕ 1 0 kW 1.5 kW 2 kW 2.5 kW 3 kW 4 kW
SimultaneouS load CharaCteriStiC