14 kVA Kohler Three Phase Multi Process DC Arc Welder Generator_Manual
21/04/21 C1KS1021_EN
ENGLISH
ENGLISH
M
1.5
TECHNICAL DATA
GENERATOR TS 405 EVO MULTI4
Three-phase power 14 kVA (11.2 kW) / 400 V / 20.2 A
Single-phase power 8 kVA / 230 V / 34.8 A
Single-phase power 4 kVA / 110 V / 36.4 A
Single-phase power 5 kVA / 48 V / 104 A
Frequence 50 Hz
ALTERNATOR self-excited, self-regulated, brushless
Type three-phase, asynchronous
Insulating class H
ENGINE
Mark / Model KOHLER KDW 1003
Type / Cooling system Diesel 4-Stroke / water
Cylinders / Displacement 3 / 1028 cm
3
Net power Stand-by 17.2 kW (23.4 HP)
Power 3000 rpm
Fuel consumption (Welding 60%) 3.3 l/h
Engine oil capacity 2.4 l
Starter Electric
GENERAL SPECIFICATIONS
Battery 12 Vdc -50Ah
Fuel tank capacity 38 l
Running time (Welding 60%) 11.5 h
Protection IP 23
*Dimensions max. Lxwxh 1649 x 710x 931
*Weight 455 Kg
Measured acoustic power LwA (LpA pression) 94.7 dB(A) (69.7 dB(A) @ 7 m)
Guaranteed acoustic power LwA (LpA pression) 96 dB(A) (71 dB(A) @ 7 m)
* Dimensions and weight are inclusive of all parts
REV.0-08/21
2000 /14/CE
CAUTION
RUNNING-IN
During the rst 50 hours of operation, do not use more than 60% of the maximum output power of the unit and check the oil
level frequently, in any case please stick to the rules given in the engine use manual.
!
POWER
Declared power according to ISO 3046-1 (temperature 25°C, 30% relative humidity, altitude 100 m above sea level).
It’s admitted overload of 10% each hour every 12 h.
In an approximative way one reduces: of 1% every 100 m altitude and of 2.5% for every 5°C above 25°C.
ACOUSTIC POWER LEVEL
ATTENTION: The concrete risk due to the machine depends on the conditions in which it is used. Therefore, it is up to the end-
user and under his direct responsibility to make a correct evaluation of the same risk and to adopt specic precautions (for
instance, adopting a I.P.D. -Individual Protection Device)
Acoustic Noise Level
(LWA) - Measure Unit dB(A): it stands for acoustic noise released in a certain delay of time. This is not
submitted to the distance of measurement.
Acoustic Pressure (Lp) - Measure Unit dB(A): it measures the pressure originated by sound waves emission. Its value changes
in proportion to the distance of measurement.
The here below table shows examples of acoustic pressure (Lp) at different distances from a machine with Acoustic Noise Level
(LWA) of 95 dB(A)
Lp a 1 meter = 95 dB(A) - 8 dB(A) = 87 dB(A) Lp a 7 meters = 95 dB(A) - 25 dB(A) = 70 dB(A)
Lp a 4 meters = 95 dB(A) - 20 dB(A) = 75 dB(A) Lp a 10 meters = 95 dB(A) - 28 dB(A) = 67 dB(A)
PLEASE NOTE: the symbol when with acoustic noise values, indicates that the device respects noise emission limits
according to 2000/14/CE directive.
2000 /14/CE
43