14 kVA Kohler Three Phase Multi Process DC Arc Welder Generator_Manual
14/04/21 Manutenzione Periodica Kohler KDW 702 - KDW 1003_EN
ENGLISH
ENGLISH
REV.0-04/21
IMPORTANT
The information given in the table is only indicative. Specic
instructions are given in the operation manuals.
The engine and alternator manufacturers indicate specic
maintenance and control intervals: it is obligatory to consult
the books, OPERATION AND MAINTENANCE of the engi-
ne and alternator provided with the generator you are using.
If such documents are not supplied with the generator set,
ask for a copy to the customer service.
ATTENTION
For the canopied machines there are routine
maintenance operations that require that the
operator climbs on top of the machine at a
height higher than 2 m. Always wear non-slip
shoes and use approved ladders or do it with
the assistance of a second operator.
!
+
The information given in the table is only indicative. Specic instructions are given in the operation manuals.
FREQUENCY
Every 8 h
or 1 year
Every 200 h
or 1 year
Every 1000 h
or 1 year
Beyond
Check of fan belt X
Check of cooling liquid level X
Check of the oil sump level X
Check presence of water in the fuel pre-lter X
Check of battery liquid (see pag. M 20) X
Check presence of water in the fuel tank X
Check of power panel and cable tightening X
Check of the air inlets and outlets of the gene-
rator set and alternator
X
Check of warning labels X
Check of hardware and ttings tightening X
Check of alternator, battery charger, start
motor
X
Check of jets / injectors X
Check of alternator bearing(s) 5000 h
Air lter cleaning X
Radiator cleaning / hoses check out X
Cleaning of fuel tank and bounding basin X
Adjustment of valve / rocker clearance X
Partial engine overhaul 5000 h
Full engine overhaul 10000 h
Fuel lter cartridge change X
Oil change, cartridge change of oil and air
lters
X
Exhaust mufer change (only for versions S
or SX)
8000/10000 h
Change of the alternator bearing(s) 8000/10000 h
Change of the coolant X
Change of the acoustic foam on the canopy
(GE versions S or SX)
10000h or 3 years
MAINTENANCE SCHEDULED
KOHLER KDW 702 - KDW 1003
41